Draft Colden Chapter #101 Battery Energy Storage Systems
  Planning Board Revision #15 (dated 8/10/26)

  11. Erosion and sediment control and storm water management plans prepared to New York State
  Department of Environmental Conservation standards, if applicable, and to such standards as may be
  established by the Planning Board.
  12. Prior to the issuance of the building permit or final approval by the Colden Town Board, but not
  required as part of the application, engineering documents must be signed and sealed by a NYS
  Licensed Professional Engineer.
  13. Emergency Operations Plan. A copy of the approved Emergency Operations Plan shall be
  given to the system owner, the local fire department, and local fire code official. A permanent
  copy shall also be placed in an approved location to be accessible to facility personnel, fire
  code officials, and emergency responders. The emergency operations plan shall include the
  following information:
  (a) Procedures for safe shutdown, de-energizing, or isolation of equipment and systems
  under emergency conditions to reduce the risk of fire, electric shock, and personal
  injuries, and for safe start-up following cessation of emergency conditions.
  (b) Procedures for inspection and testing of associated alarms, interlocks, and controls.
  (c) Procedures to be followed in response to notifications from the Battery Energy Storage
  Management System, when provided, that could signify potentially dangerous
  conditions, including shutting down equipment, summoning service and repair
  personnel, and providing agreed upon notification to fire department personnel for
  potentially hazardous conditions in the event of a system failure.
  (d) Emergency procedures to be followed in case of fire, explosion, release of liquids or
  vapors, damage to critical moving parts, or other potentially dangerous conditions.
  Procedures can include sounding the alarm, notifying the fire department, evacuating
  personnel, de-energizing equipment, and controlling and extinguishing the fire.
  (e) Response considerations similar to a safety data sheet (SDS) that will address
  response safety concerns and extinguishment when an SDS is not required.
  (f) Procedures for dealing with battery energy storage system equipment damaged in a fire
  or other emergency event, including maintaining contact information for personnel
  qualified to safely remove damaged battery energy storage system equipment from the
  facility.
  (g) Other procedures as determined necessary by the Town of Colden to provide for the
  safety of occupants, neighboring properties, and emergency responders.
  (h) Procedures and schedules for conducting drills of these procedures and for training local
  first responders on the contents of the plan and appropriate response procedures.
I. Special Use Permit Standards.
  1. Setbacks. Tier 2 Battery Energy Storage Systems are only permitted in Ag-Zoning districts
  and shall have a front setback no less than 300’ from the edge of the road frontage Right
  of Way. The side boundary setbacks shall be no less than 50’ from the side yard
  boundary lines. The rear yard setback shall be no less than 100’ from the parcel’s rear
  boundary line. For all situations the site plan shall take into account neighboring
  dwellings and/or commercial structures which are considered by this Chapter as non-
  participating entities. The distance from the applicant’s BESS structure(s) to the nearest
  non-participating entity on all nearby parcels shall always meet a structure-to-structure
  distance of at least a 200 feet.