P.T. (2) 2X10 FRONT GIRDER BEAM ON PT 4X4 POSTS VIA SIMPSON BCS2-2/4 CONNECTOR 16"Ø SONOTUBE FOOTER @ 48" DEPTH MIN W/ PT 4X4 AND SIMPSON BCS2-2/4 CONNECTOR SIMPSON DTT1 TENSION EVERY 4 JOISTS SIMPSON DTT2 TENSION TIE AT EACH HAND RAIL POST SIMPSON LUC JOIST HANGAR AT EACH JOIST SEALED CRAWL SPACE NEW INTERIOR DRAIN TILE TO EMPTY INTO SUMP NEW 3" TAPCO METAL COLUMNS ON NEW FOOTERS JACKPOST DETAIL 2 CRAWL SPACE FOOTING DETAIL 4 SCALE: NTS S-3 SCALE: NTS S-3 8'-9" 8" 10" MIN. 7'-6" CEILING HEIGHT 10" 8" BLOCK WALL TO BE REPAIRED TO MATCH EXISTING W/ #4 BAR VERTICAL @ 4' FULL GROUT AND 18" NEW SUMP 18"Ø @ 24" DEPTH DURAWAY HORIZONTAL RE-ENFORCEMENT @ 16" ADDITION FRAMING PLAN 1 FOUNDATION WALL DETAIL 3 SCALE: 3/8"=1'-0" S-3 SCALE: NTS S-3 SCHENNE & ASSOCIATES CONSULTING ENGINEERS BRIAN ARCHER HOME RENOVATION FOUNDATION PLAN 967 Luther Road 417 PROSPECT AVE, 417 PROSPECT AVE, East Aurora, NY 14052 (716) 655-4991; [email protected] EAST AURORA, NY 14052 EAST AURORA, NY 14052 SCALE: AS NOTED DATE: 20260326 DWG. S-3