Text · page 48 of 117
Read the whole document on one page (all 117 pages, each with its own heading)
□------□ SPECIFICATIONS BOMAN KEMP 4040 "EASY-BUCK" BOMAN KEMP 4040 SEE BOWMAN KEMP MANF. DETAILS FOR DOUBLE INSULATED VINYL WINDOW WINDOW WELLS r------7 / I I DIVISION 1: GENERAL REQUIREMENTS FINISH HARDWARE 34'-3" 34'-3" INTERIOR HARDWARE SHALL BE IN A COLOR AND MANUFACTURER AS SELECTED BY THE I I 7'-8" GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR EXECUTION OF WORK DESCRIBED IN OWNER, LEVER STYLE (HANDICAP ACCESSSIBLE). OWNERS TO INDICATE LOCATIONS OF r ---------- -------- ------- -, ~ ! ! THESE CONSTRUCTION DOCUMENTS. LOCKSETS AND ADDITIONAL HARDWARE NEEDS. I -----------------------------~ I l) <I! 3'-0" Ix 4'-8" 3'-0" x 4'-8" q,/ I I GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL PERTINENT PERMITS GLAZING ,-------~-------~------- SUPPLY I SUPPLY AND MAKE ALL ARRANGEMENTS FOR INSPECTIONS REQUIRED BY THE GOVERNING BODY OR ALL GLAZING SHALL MEET IBC FOR STRUCTURAL CHARACTERISTICS. TYPE OF GLASS AS ' 16'-0" 7 ' I 18'-3" DBL. HUNG ! 16'-0" DBL. HUNG 3-0 II 18'-3" I ' MUNICIPALITY. SELECTED BY OWNER IF ORNAMENTAL LOCATIONS ARE SPECIFIED. FULL F.V. CODE COMPLIANT VIEW 2'-6" x 4'-8" STEPS TO GRADE ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS AND SHALL BE IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE, LATEST EDITION. DIVISION 9: FINISHES DBL. HUNG 3S ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE NYS ENERGY CONSERVATION GYPSUM BOARD BASEMENT 3S CONSTRUCTION CODE, LATEST EDITION. GYPSUM WALLBOARD IS REQUIRED ON ALL WALLS AND CEILINGS IN HABITABLE SPACES. e WALLBOARD SHALL BE1/2" THICK OR AS INDICATED ON THE CONSTRUCTION DOCUMENTS. 0S ------ - ALL WORK SHALLBE PERFORMED BY PERSONS EXPERIENCED WITH THIS TYPE OF WORK DESCRIBED HEREIN. MATERIALS USED FOR THIS PROJECT SHALL BE NEW AND MANUFACTURED FOR THE PURPOSE INDICATED ON THE CONSTRUCTION DOCUMENTS. SEE PLANS FOR FIRE RATED CONSTRUCTION APPLICATIONS. MOISTURE RESISTANT WALLBOARD SHALL BE USED IN BATHROOMS AND AREAS SUSCEPTIBLE TO MAOISTURE. -o\ ✓- -◊ 16" X 42" CONCRETE PIER WITH SIMPSON BRACKET, 6X6 PT POST, TYP. BEDROOM WEATHERPROOF 16'-3" PAINTING ~D 16'-0" CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL DIMENSIONS, GRADE ELEVATIONS, PAINT AND INTERIOR STAIN SHALL BE AS MANUFACTURED BY 'BENJAMIN MOORE' OR AN I S COVERED PATIO UTILITY LOCATIONS AND SERVICE CONNECTIONS PRIOR TO THE COMMENCEMENT OF WORK. APPROVED EQUAL. ALL FINISHED PAINTING SHALL BE ONE COAT OF PRMER AND TWO I FINISHED COATS. ITEMS TO BE STAINED SHALL INCLUDED FINAL COAT OF VARNISH. CEILING FRAMING ABOVE: 2x8's I ANY DIMENSIONAL DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION, I I IN WRITING, PRIOR TO THE FABRICATION OR ERECTION OF CONSTRUCTION COMPONENTS. DIVISION 10: SPECIALTIES I I 23'-521 " 24'-0" 24'-0" 24'-0" I e WALLS: 8" WIDE, 8" X 18" CONTINUOUS FOOTING 23'-6" DIVISION 2: SITEWORK STORAGE SHELVING ALL STORAGE SHELVING SHALL BE 3/4" PLYWOOD FINISHED WITH END STRIPS AND I 3) #4 BARS CONTINUOUS IN FOOTING, WALLS REINFORCED I #4 BAR 32" OC HORIZONTAL & VERTICAL I I DBL. HUNG SUBSURFACE INVESTIGATION: GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SITE PREPARATIONS INCLUDING CLOSET RODS SHALL BE STEEL OR AS APPROVED BY OWNER. BLOCK IN ALL ACCESSORY LOCATIONS BEHIND WALL. DIVISION 15: MECHANICAL N I I COVERED PATIO 2'-6" x 4'-8" 2X4 AT 16" O.C., 3- PLATE WALLS ALL WALLS HAVE WOOD CORNERS AND MIN. 2X10X2 HEADERS UNLESS UTILITY SEARCHES AND UNDERGROUND INVESTIGATIONS AS REQUIRED BY LOCAL ORDINANCES. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SOIL EVALUATION AS THEY PERTAIN TO I I / / ---- -' " NOTED OTHERWISE FOR INT. WALLS PT 6X6 158 WEST FILLMORE AVE., EAST AURORA, NEW YORK 14052 ~) THIS PROJECT UNLESS OTHERWISE PROVIDED BY OWNER. I,, RETURN ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH ASHRAE GUIDELINES FOR DESIGN <}/ PROPERTY LINE SITE PREPARATIONS: GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ADEQUATE SITE CLEARING AND AND INSTALLATION. <>--, WEATHERPROOF 2'-6" GRADING TO PROVIDE A SAFE WORKPLACE. ALL PLUMBING WORK SHALL BE AS PER NYS PLUMBING GUIDELINES FOR DEISGN AND \ INSTALLATION. \ LANDSCAPING: FLOOR FRAMING ABOVE: 2x10's I I ->- GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE GRADING AND LAWN PLACEMENT ALL MATERIALS SHALL CONFORM TO INDUSTRY STANDARDS. FLOOR JOISTS @ 12" OC 7'-9" DBL. JOISTS UNDER PARALLEL PARTITIONS I CL. 7'-121 " AS PER THE AGREEMENT MADE BETWEEN THE CONTRACTOR AND THE OWNER. ALL FOUNDATION THE COLE RESIDENCE GRADING SHALL MEET MUNICIPAL GRADE REQUIREMENTS AND DRAIN AWAY FROM THE BUILDING TO AREAS DESIGNATED BY THE MUNICIPALITY. DIVISION 16: ELECTRICAL I I 2-6 PKT. I NEW FLOORING TO ALIGN ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE I S WITH EXISTING LEVEL DIVISION 3: CONCRETE FOR DESIGN AND INSTALLATION. CONCRETE ALL MATERIALS SHALL CONFORM TO INDUSTRY STANDARDS FOR THE SAME. ' n I LI 71 II S / I r ' LI I- - - - - - "ll) I 7'-221 " 3-0 POCKET 3S S3 4'-0" FORMWORK SHALL BE WOOD OR METAL AS USED BY THE CONTRACTOR. ALL FORMWORK I S3 S RETURN LIGHTING SCHEDULE \__ATTACH NEW FOUNDATION TO EXISTING: #6 DOWEL, 12" LONG LINEN 2'-0" SHALL MEET OR EXCEED INDUSTRY STANDARDS FOR THE TYPE USED AND SHALL BE SET ~ I REMOVE EXISTING WINDOW, 2'-8" TRUE AND LEVEL. TOWER PROVIDE ACCESS TO NEW CONCRETE REINFORCING CONDUCTORS SHALL BE COPPER AND HAVE THHN INSULATION. ALL WIRE SHALL BE NEW BASEMENT SPACE, F.V. LOCATION DRILLED AND GROUTED INTO EXISTING AT 12" OC VERTICALLY. DOWEL TO BE FULLY GROUTED, WATERPROOF CONNECTION e GFI " _.,. . ' 3'-0" 2-6 BI-PASS ALL REINFORCING SHALL MEET BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, I AND HAVE SIZE AND INSULATION TYPE INDICATED ON IT'S COVER. ALL WIRE SHALL HAVE HALF WALL .'S SI 0 LATEST EDITION. WIRE REINFORCING SHALL CONFORM TO ASTM A82. STEEL REINFORCING BEEN MANUFACTURED IN ACCORDANCE WITH THE LATEST APPLICABLE CODES. ALL WORK CL. BATH 4'-0" I _I,,- / SHALL CONFORM TO ASTM A65, GRADE 60. PROTECTION FOR REINFORCING CONCRETE SHALL BE IN ACCORDANCE WITH NEC, OSHA, AND LOCAL CODES. ,I ·-.1 3-0 IS AS FOLLOWS: . DIRECT EXHAUST..1- POCKET FOOTINGS: 3" COVER BOTTOM AND SIDES ANY ITEMS NOT SPECIFIED ON THE DOCUMENTS, BUT REQUIRED TO COMPLETE THIS PROJECT BATHROOM TO THE EXTERIOR PIERS AND WALLS: 2" COVER ALL AROUND ·\ . SLABS: 3/4" COVER AT MAIN REINFORCING SHALL BE INSTALLED PER GENERALLY ACCEPTED STANDARDS. TYP. ALL BATHROOMS . ' \. I I "T KITCHEN CONDUIT SHALL BE EMT WITH ALL REQUIRED FITTINGS, WHERE FLEXIBLE RACEWAY IS REQUIRED, I 1'-6" X ' BATH -- S C COVERED PATIO 1'-6" CAST-IN-PLACE CONCRETE 3'-6" DH I I USE MC CABLE IS ALLOWABLE BY LOCAL CODES. ALL CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS. FROSTED GLASS ., I 3'-0" • ' EXTERIOR CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 4000 PSI. I SUPPLY SIDEWALK SHALL INCLUDED 5X5 MESH REINFORCING, CONTROL JOINTS AT MAX OF 4'-0", PROVIDE FIRESTOPPING THROUGH ALL FIRE WALLS. ., 421 " PITCH AWAY FROM BUILDING. _, 1 ALL RECEPTACLES, PHONE JACKS, ETC., SHALL BE FLUSH MOUNTED AT 18" AFF AND SHALL - TILES WALL, 3'-121 " 2 ' DIVISION 5: METALS BE COMPLETE WITH THERMOPLASTIC COVER PLATE THAT MATCHES THE ADJACENT FINISHES. 4'-6" L ~ GLASS TO CEILING L ABOVE NEW DOORS THROUGHOUT ALL PANELS SHALL BE MANUFACTURED BY 'ITE', 'SQUARE D' OR APPROVED EQUAL. -, . . . THE MAIN FLOOR TO MATCH STRUCTURAL STEEL NEW ADDITION - I I I I 12" ALL STRUCTURAL STEEL SHALL BE AS INDICATED ON THE CONSTRUCTION DOCUMENTS, BUT SMOKE DETECTORS SHALL BE TWO WIRE PHOTOELECTRIC - 2400 SERIES SHAMPOO RECESS S3 AIR BARRIERS & INSTALLATION NOT LIMITED TO SAME. ALL STRUCTURAL STEEL SHALL CONFORM TO SPECIFICATION FOR SYSTEM SHALL BE HARDWIRED AND INTERCONNECTED, LOCATIONS PER NFPA STANDARD THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS OF THE CODES AND INSTALLED IN CONCERT WITH SECURITY SYSTEM IF APPLICABLE. AMERICAN INSTITUTE OF STEEL CONSTRUCTION, LATEST EDITION. 8'-121 " STEEL PLATES & SHAPES: ASTM A-36 PLUMBING FIXTURE SCHEDULE TILE SEAT PIPE COLUMNS: ASTM A-53 COMPONENT AIR BARRIER CRITERIA INSULATION CRITERIA SEAMLESS GRADE B-NUTS & BOLTS: ASTM A-325 KOHLER: WATER CLOSET PROPERTY LINE ANCHOR BOLTS: ASTM A- 307 COLOR: AS SELECTED BY OWNER GENERAL REQUIREMENTS 1. CONTINUOUS AIR BARRIER SHALL BE INSTALLED AT THE BUILDING ENVELOPE. REMOVE EXISTING BASE MOLDING, REPLACE ALL STRUCTURAL STEEL SHALL RECEIVE A PRIME COAT OF RUST INHIBITIVE PAINT. 2. THE EXTERIOR THERMAL INSULATION SHALL HAVE A CONTINUOUS AIR BARRIER. WITH NEW TO MATCH ADDITION, PAINT LIVING ROOM LAVATORY INTEGRATED INTO COUNTER 3. ANY BREAKS OR JOINTS SHALL BE SEALED. DINING DIVISION 6: WOOD & PLASTICS COLOR: AS SELECTED BY OWNER CEILING / ATTIC 1. THE AIR BARRIER IN ANY DROPPED CEILING/SOFFIT SHALL BE ALIGNED WITH THE INSULATION SHALL ALIGN WITH THE AIR BARRIER GARAGE FAUCET STYLE AS SLECTED BY OWNER THE INSULATION. COLOR: AS SELECTED BY OWNER ROUGH CARPENTRY 2. ANY GAPS SHALL BE SEALED. ALL FRAMING LUMBER SHALL BE INDICATED ON THE CONSTRUCTION DOCUMENTS. ALL SHOWER HEAD AND MIXERS: AS SELECTED BY OWNER 3. ANY OPENINGS (ATTIC HATCH, ETC.) TO UNCONDITIONED ATTICE SPACE PRESSURE TREATED WOOD SHALL BE EMPLOYED AT AREAS EXPOSED TO THE WEATHER TOILET TISSUE, TOWEL BARS AND MIRROR: SHALL BE SEALED. FAMILY ROOM OR IN CONTACT WITH SOIL OR FOUNDATIONS. PROVIDED BY OWNER WALLS 1. THE JUNCTION OF THE FOUNDATION AND SILL PLATE SHALL BE SEALED. 1. CAVITIES TO BE COMPLETELY FILLED WITH INSULATION WITH A MIN. R-3 RATING EXTERIOR GRADEPLYWOOD SHEATHING SHALL BE USED AT WALLS AND ROOF DECK AREAS. COLOR & STYLE: AS SELECTED BY OWNER 2. THE JUNCTION OF THE TOP PLATEAND THE TOP OF THE EXTERIOR WALL 2. EXTERIOR INSULATION TO BE IN CONTACT AND ALIGNMENT WITH THE AIR BARRIER. SHALL BE SEALED. ALL STRUCTURAL FRAMING MEMBERS SHALL BE DOUGLAS FIR OR MANUFACTURED 3. KNEE WALLS SHALL BE SEALED. PRODUCTS AS INDICATED ON CONSTRUCTION DOCUMENTS. HEADER SCHEDULE DESIGN DATA LUMBER PROPERTIES SHALL BE AS FOLLOWS: DOUG FIR: Fb:1450, Fc:1050. OPEN SIZE HEADER SNOW LOAD: 55# PER SQUARE FOOT ALL FRAMING SHALL BE 2X4 OR 2X6 STUDS AT 16" OC, HEM FIR #2 Fb:1350, Fc:825. UP TO 3'-0" (2) 2X6'S WIND LOAD: 115 MILES PER HOUR UP TO 6'-0" (2)2X10'S SEISMIC DESIGN AREA: 4 WINDOWS, SKYLIGHTS & DOORS 1. THE GAP BETWEEN THE WINDOWS, DOOR JAMBS TO FRAMING TO BE SEALED. ALL LAMINATED STRUCTURAL ELEMENTS SHALL BE AS MANUFACTURED BY LOUSIANA- UP TO 9'-0" (2) 2X12'S LIVE LOAD: 40# PER SQUARE FOOT 2. THE GAP BETWEEN SKYLIGHTS TO FRAMING TO BE SEALED. PACIFIC OR AN EQUAL ALTERNATE. APPROVAL OF ALTERNATES SHALL BE UP TO 13'-0" (3) 2X12'S SUBMITTED TO THE ARCHITECT IN WRITING. ARCHITECTURAL WOODWORK RIM JOIST THE RIM JOIST SHALL INCLUDED AN AIR BARRIER RIM JOIST TO BE INSULATED WITH THE SAME INSULATION AS THE WALLS. STAIR PARTS SHALL BECONSTRUCTED TO MEET IBC FOR STRUCTURAL CHARACTERISTICS AND MECH. DESIGN SHALL INCLUDE ALL PARTS FOR CODE COMPLIANT INSTALLATION. FLOORS (CANTILEVERS AND FLOORS AN AIR BARRIER SHALL COVER ANY EXPOSED INSULATION INCLUDING ENDS. OVER GARAGE) 6'-321 " PLASTIC FABRICATIONS ALL PLASTIC LAMINATES SHALL E AS MANUFACTURED BY FORMICA OR APPROVED ALTERNATE. ENTRY TOPS SHALL BE ADHERED TO WOOD SUBSTRATES PER INDUSTRY STANDARDS. CRITERIA CRAWL SPACE FLOOR AND WALL A CLASS 1 VAPOR BARRIER RETARDER SHALL BE INSTALLED OVER A CRAWL SPACE FLOOR DIVISION 7: THERMAL & MOISTURE PROTECTION SHAFT PENETRATIONS DUCT SHAFTS, UTILITY PENETRATIONS AND FIRE SHAFT OPENINGS TO EXTERIOR OR UNCONDITIONED SPACE SHALL BE SEALED. NORTH DAMPROOFING INDOOR DESIGN TEMPERATURES: MAIN FLOOR PLAN FOUNDATIONS SHALL BE DAMPROOFED WITH A 'DELTA-MS' MAT INSTALLED PER HEATING: 72 DEGREES F (MAX) NARROW CAVITIES AN AIR BARRIER SHALL BE EXPOSED IF EXPOSED TO AN EXTERIOR OR INSULATION IN NARROW CAVITIES SHALL BE CUT TO FIT OR CAVIITIES SHALL BE MANUFACTURERS REQUIREMENTS FOR FULL HEIGHT FOUNDATIONS OR 2 COATS OF SPRAY COOLING: 75 DEGREES F (MIN) UNCONDITIONED SPACE FILLED WITH INSULATION THAT READILY CONFORMS TO CAVITIY SPACE. ON WATERPROOFING IF INDICATED OTHERWISE. CONTRACTOR SHALL ENSURE THAT ENTIRE □------□ SURFACE IS COVERED. MASONRY BLOCK WALLS SHALL BE SEALED PER MASONRY STANDARDS. OUTDOOR DESIGN TEMPERATURES: GARAGE AIR SEALING SHALL BE PROVIDED BETWEEN GARAGES AND CONDITIONED 1/4" = 1'-0" HEATING: 6538 DEGREE DAYS SPACES. □------□ INSULATION COOLING: 558 DEGREE DAYS HEATHER M. NEMEC ALL INSULATIONS SHALL BE INSTALLED AS INDICATED ON THESE CONSTRUCTION DOCUMENTS ARCHITECT AND/OR PER THE NYS ENERGY CONSERVATION CONSTRUCTION CODE, LATEST EDITION. RECESSED LIGHTING RECESSED LIGHTING FIXTURES INSTALLED IN THE BUILDING THERMAL RECESSED LIGHTING FIXTURES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO THE DRYWALL. ENVELOPE SHALL BE AIR TIGHT AND IC RATED. HVAC MINIMUM EQUIPMENT EFFICIENCIES: 8639 FINCH ROAD SHINGLE ROOFING COLDEN, NEW YORK 14033 ROOF SHINGLES SHALL BE AS MANUFACTURED BY 'IKO' OR AS SELECTED BY THE OWNER. COOLING: SPLIT SYSTEM PHONE (716) 907-1500 PLUMBING & WIRING INSULATION SHALL BE CUT TO FIT AROUND WIRING AND PLUMBING IN STYLE, COLOR AND TYPE SHALL BE AS SELECTED BY OWNER. SHINGLES SHALL BE AC 13 SEER, HP 14 SEER, 8.0 HSPF E-MAIL: INSTALLED IN A MANNER ACCEPTABLE TO THE INDUSTRY. EXTERIOR WALLS, INSULATION SHALL READILY CONFORM TO AVAILABLE SPACE [email protected] HEATING: GAS FURNACE IN AREA INSTALLED. FLASHING & SHEET METAL 80 AFUE ALL FLASHING SHALL BE ALUMINUM AND SHALL PROVIDE MINUMUM 8'-0" VERTICAL PROTECTION. MATERIALS SHALL BE COMPATIBLE WITH ADJACENT MATERIALS. WATER HEATING: SHOWERS & TUBS INSULATION SHALL BE INSTALLED AROUND SHOWERS AND TUBS INSTALLED GAS STORAGE, GREATER THAN 55 GALLONS ADJACENT TO EXTERIOR WALLS AND UNCONDITIONED SPACES. GUTTERS & DOWNSPOUTS 0.80 (0.0182 - (0.00078 X VOLUME) ALL GUTTERS AND DOUWNSPOUTS SHALL BE ALUMINUM (SEAMLESS) AS MANUFACTURED BY 'ALCOA PRODUCTS'. STYLE, SHAPE AND COLOR AS SELECTED BY THE OWNER. ELEC. / PHONE ON EXT. WALLS AN AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL AND PHONE BOXES OR AIR SEALED BOXES SHALL BE INSTALLLED. JOINT SEALERS ALL JOINT SEALERS SHALL BE EMPLOYED AT CONNECTIONS TO THE BUILDING AND AS ELEC. NOTES INSTALLED IN A MANNER ACCEPTABLE TO THE INDUSTRY. HVAC REGISTER BOOTS HVAC REGISTER BOOTS THE PENETRATE THE BUILDING ENVELOPE TO BE SEALED TO THE FLOOR AND DRYWALL. DIVISION 8: DOORS & WINDOWS □------□ ELEV. & METAL DOORS & FRAMES PLAN NYS ENERGY CODE COMPLIANCE TABLE EXTERIOR DOORS SHALL BE STEEL INSULATED IN A STYLE AND COLOR AS SELECTED BY 1. CONDUCTORS TO BE COPPER WITH THIN INSULATION. THE OWNER. 2. CONDUCTORS TO HAVE BEEN MANUFACTURED WITHIN ONE PERMIT: YEAR OF INSTALLATION. WOOD DOORS 3. CONDUCTORS TO BE STRANDED AND #12 ASW CAD FILE: COLE2025 INTERIOR WOOD DOORS SHALL BE SIZED AS INDICATED ON THE PLANS WITH A MIN. HT. CHAPTER 11 - ENERGY EFFICIENCY INTERNATIONAL RESIDENTIAL CODE DRAWN BY: HMN 4. PANEL BOARD SCHEDULE TO BE PROVIDED. OF 6'-8" UNLESS NOTED OTHERWISE. DOORS TO BE COLONIST SIX PANEL PREHUNG UNLESS CLIMATE ZONE #5A ERIE COUNTY - TABLE N1102.1.2 (R402.1.2) COPYRIGHT 2025 5. ANY CONDUIT TO BE METAL CLAD. INDICATED OTHERWISE. 6. BUSHINGS TO BE INSTALLED IN ANY CONDUIT ENDS. HEATHER M. NEMEC, ARCHITECT 7. ANY CONDUCTORS IN CONCRETE TO BE IN 4" PVC PIPE. □------□ FENESTRATION U FACTOR SKYLIGHT U FACTOR GLAZED FENESTRATION SHGC CEILING R VALUE WOOD FRAME WALL R VALUE MASS WALL R VALUE FLOOR R VALUE BASEMENT WALL R VALUE SLAB DEPTH & R VALUE CRAWL SPACE R VALUE WINDOWS 8. SWITCHES TO BE 48" ABOVE THE FLOOR. WINDOWS AS INDICATED ON THE PLANS, MANUFACTURED BY 'ANDERSEN', 400 SERIES, 9. RECEPTICALES TO BE 12" ABOVE FLOOR. R-49 OR R-38 R-15 CONT. OR R-21 R-15 CONT. OR R-21 I, HEATHER M. NEMEC, ARCHITECT, CERTIFY THAT TO THE BEST OF MY KNOWLEDGE .35 MAX - R-20 OR R-13.5 MIN. 13/17 MIN. R-30 MIN. R-10 TO 2'-0" □------□ CODE .55 MAX OR 'PELLA' PROLINE, OR APPROVED EQUAL. ALTERNATE WINDOWS MAY BE USED UNDER 10. SMOKE DETECTORS/ALARMS AND CO DETECTORS TO FOR ENTIRE CEILING CAVITY CAVITY THAT THESE PLANS ARE IN COMPLIANCE WITH THE ENERGY CODE A-1 THE FOLLOWING CONDITIONS: HAVE A DEDICATED SYSTEM. THEY MEET LIGHT AND EGRESS REQUIREMENTS AS SET FORTH IN THE IBC AND ENERGY 11. TV AND PHONE SYSTEMS TO HAVE A DEDICATED SYSTEM. ACTUAL .32 & .33 NONE - R-49 R-21 NONE NONE R-21 NONE NONE CONSERVATION CONSTRUCTION CODES. 10 JULY 2026 SIGNATURE DATE □ □