25-4181 storm calcs - proposed  Type II 24-hr 1-Year Rainfall=1.87"
Prepared by Carmina Wood Design  Printed 2/11/2026
HydroCAD® 10.20-8a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 7

  Time span=0.50-70.00 hrs, dt=0.04 hrs, 1739 points
  Runoff by SCS TR-20 method, UH=SCS, Weighted-CN
  Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method

Subcatchment 2S: Proposed Site  Runoff Area=53,039 sf 53.36% Impervious Runoff Depth=0.98"
  Flow Length=368' Tc=7.4 min CN=90 Runoff=2.00 cfs 4,350 cf

Pond 3P: Underground Detention  Peak Elev=526.60' Storage=1,104 cf Inflow=2.00 cfs 4,350 cf
  8.0" Round Culvert n=0.013 L=24.0' S=0.0050 '/' Outflow=0.96 cfs 4,350 cf

  Total Runoff Area = 53,039 sf Runoff Volume = 4,350 cf Average Runoff Depth = 0.98"
  46.64% Pervious = 24,735 sf 53.36% Impervious = 28,304 sf

  Page 37 of 65