A. Required plans. A building permit application shall be made to the Director of
Development and shall be accompanied by:
(1) A complete set of construction plans drawn accurately to scale or a copy of literature
and plans or sketches provided by the pool manufacturer in a form acceptable to the
Department of Development.
(2) A complete set of plot plans showing all lot lines, existing structures and yard
measurements, drawn accurately to scale.
B. Engineer or architect. All plans for private, permanent swimming pools of a capacity
in excess of 1,500 cubic feet contained within a building or erected above or below
ground level shall be designed by a licensed New York State professional engineer or
architect.
C. See § 75-16 for fees.
§ 198-5 Accessory buildings.
A bathhouse, cabana, pump house, filter house or other structure erected in connection
with any such private pool shall require a building permit and shall comply with the State
Building Construction Code[1] and the City of Lackawanna Zoning Ordinance[2] and
any and all local laws and ordinances and any amendments hereafter adopted.
[1]Editor's Note: See Ch. 75, Building Construction.
[2]Editor's Note: See Ch. 230, Zoning.
§ 198-6 Plumbing permit.
A. Required. All plumbing and drainage connected therewith shall comply with the State
Building Construction Code and shall require a plumbing permit.
B. Fees; drawings. Plumbing permit applications shall be accompanied by:
(1) The appropriate fee as established from time to time by the Council.
(2) Complete detailed drawings, showing filling or feed system, filtration and/or
purifying system and drainage system.
§ 198-7 Drain, grate and drainage.
A. All excavated private pools of 1,500 cubic feet capacity and larger shall have a drain
and each drain shall be covered by a grate four times the area of the drainpipe. The grate
shall be removable only by the use of a hand tool. Where gravity is impractical, proper
drainage shall be provided to a storm sewer.