Text · page 67 of 93
Read the whole document on one page (all 93 pages, each with its own heading)
HAMBURG SIA DISTRICT ZONING 8 5) Concealing unappealing functions. Site layout shall be designed to minimize impact, visibility, and public view of service areas, loading docks, dumpsters, utilities, and other utilitarian functions of the property. The site layout should place these components on the side of the building with the fewest number of expected pedestrians to the degree practicable. In areas likely to be seen by pedestrians, these functions should be buffered with site landscaping, architectural screening, and fencing. Chain link fencing is not acceptable for screening purposes. 6) Mechanical equipment: Mechanical equipment, including metal chimneys and elevator penthouses at grade, attached to, or on the roof of a building, shall be screened from the view of the most adjacent street or driveway or they should be integrated into the overall design of the building through use of materials, placement, roof shape or form, or other means. E. Site standards for dwellings 1) Applicability. The following is applicable to single-family and two-family dwellings. 2) Purpose. Single- and two-family dwellings shall be developed in such a way that contributes to the walkable, mixed-use nature of the SIA District. 3) Single- and two-family dwellings shall be sited on lots 3,000 SF or less. 4) Single- and two-family dwellings are suitable only for Tier 3 streets as described in Section C above. 5) Single- and two-family dwellings are not permitted within 2,000 square feet of the nearest face of the Buffalo Bills Stadium. F. Building Materials 1) Buildings must use high quality materials that contribute to a vibrant neighborhood and resist deterioration. 2) Building facade materials permitted within the SIA include, but are not limited to, brick, concrete masonry, wood, cementitious fiber board, manufactured limestone, cast stone, masonry, stone, glass, terra cotta, cellular PVC trim, tile, and sustainable materials. 3) The following building materials are prohibited on any façade visible to the general public: a) Plain concrete block b) Glass block c) Exposed aggregate (rough finish) concrete wall panels, d) Exterior insulating finish systems (EIFS) e) T-111 plywood or oriented strand board (OSB) siding. f) Plastic g) Vinyl, except cellular vinyl trim may be used as decorative or detail elements for up to 25% of the facade. h) Metal, except as decorative or detail elements for up to 30% of the facade. 67