Part II.C.2.b.iv.
  iv. Extreme Flood Control Criteria (Qf): Requires storage to attenuate
  the post-development 100-year, 24-hour peak discharge rate (Qf)
  to predevelopment rates. The Qf requirement does not apply when:

  1. the site directly discharges to tidal waters or fifth order or
  larger streams; or

  2. A downstream analysis reveals that overbank control is not
  required.

c. Sizing Criteria for Redevelopment Activity

  i. Water Quality Volume (WQv): The WQv treatment objective for
  redevelopment activity must be addressed by one of the following
  options, as outlined in Section 9.2.1. Redevelopment activities
  located in an Enhanced Phosphorus Removal Watershed (see Part
  III.B.3. and Appendix C) must calculate the WQv in accordance
  with Section 4.3 of the DM. All other redevelopment activities must
  calculate the WQv in accordance with Section 4.2 of the DM.

  1. Reduce the existing impervious cover by a minimum of 25%
  of the total disturbed, impervious area. The Soil Restoration
  criteria in Section 5.1.6 of the DM must be applied to all
  newly created pervious areas; or

  2. Capture and treat 100% of the required WQv, for a minimum
  of 25% of the disturbed redevelopment impervious area, by
  implementation of standard SMPs or reduced by application
  of runoff reduction techniques; or

  3. Capture and treat 100% of the required WQv, for a minimum
  of 75% of the disturbed redevelopment impervious area, by
  implementation of a volume-based alternative SMP, as
  defined in Section 9.4 of the DM; or

  4. Capture and treat 100% of the required WQv, for a minimum
  of 75% of the disturbed redevelopment impervious area, by
  implementation of a flow-through alternative SMP sized to
  treat the peak rate of runoff from the WQv design storm; or