Part III.B.1.c.vii.
  temporary sediment basins and structural practices that will be
  used to divert flows from exposed soils; and

  viii. A maintenance inspection schedule for the contractor(s) and
  subcontractor(s) identified in Part III.A.7. to ensure continuous and
  effective operation of the erosion and sediment control practices.
  The maintenance inspection schedule must be in accordance with
  the requirements in the BB technical standard; and

  ix. A description of the pollution prevention measures that will be used
  to control litter, construction chemicals and construction debris from
  becoming a pollutant source in the stormwater discharges; and

  x. A description and location of any stormwater discharges associated
  with industrial activity other than construction at the site, including,
  but not limited to, stormwater discharges from asphalt plants and
  concrete plants located on the construction site; and

  xi. Identification of any elements of the design that are not in
  conformance with the design criteria in the BB technical standard.
  Include the reason for the deviation or alternative design and
  provide information which demonstrates that the deviation or
  alternative design is equivalent to the technical standard.

2. SMP component – The owner or operator of construction activity identified in
  Table 2 of Appendix B must prepare a SWPPP that includes SMPs.

  a. SMPs must be designed in conformance with the applicable sizing criteria
  in Part II.C.2.a., c., or d.; and

  b. SMPs must be designed in conformance with the performance criteria:

  i. in the DM; or

  ii. equivalent to the DM if deviating from Part III.B.2.b.i.; or

  iii. in the New York State Stormwater Management Design Manual,
  dated January 2015 (2015 Design Manual), or equivalent to it, if the
  following criteria are met:

  34