Text · page 1154 of 1493
Read the whole document on one page (all 1493 pages, each with its own heading)
6"-22.5° STOP PUMP STATION UTILITY LOCATION AND SIZE WITH OE RIM 682.40 UTILITY COMPANIES AND MEP DRAWINGS 15 LF 6" SDR-35 PVC SANITARY 202 LF 8" SDR-35 BEND C.O. C.O. SAN MH 5 INV 678.40 NE UE SEWER LATERAL @ 1.0% MIN. PVC PRIVATE SAN RIM 678.00 SEWER @ 0.4%12" INV 674.68 N 4" AWWA C-900 PVC DOMESTIC INV 670.68 W, SW EA OE 71 LF 6" SDR-35 PVC SANITARY INV 673.68 N R SERVICE (MIN. 5' COVER) SEWER LATERAL @ 1.0% MIN. INV 671.59 W COORDINATE GAS, CTV AND ELECTRIC 6" AWWA C-900 PVC DOMESTIC .A BIT UE INV 671.49 E UTILITY LOCATION AND SIZE WITH WATER (MIN. 5' COVER) 170°-37'-13" sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor 675 to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration. 674 71 LF 6" SDR-35 PVC SANITARY UTILITY COMPANIES AND MEP DRAWINGS 12" All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145 OE 673 Greensboro 672 SEWER LATERAL @ 1.0% MIN. APPROX. LOCATION CONTRACTOR TO VERIFY LIMITS OF 671 670 OF CEMETERY CEMETERY AND NOTIFY DESIGN UE 18" STM INV 674.00 ENGINEER OF ANY POTENTIAL CONFLICTS 8" SAN INV 672.50 HEAD STONES NOT 673.50 LOCATED 127°-49'-44" UE 673.50 6"-22.5° 14" BEND 28" 14" Utica UE W. INV: 682.97 180 LF 8" SDR-35 4" AWWA C-900 PVC PVC PRIVATE SAN (12" HDPE) 18" MIN. VERTICAL DOMESTIC SERVICE UE Buffalo SEWER @ 0.4% SEPARATION (TYP.) 12" STM INV 677.07 (MIN. 5' COVER) 8" SAN INV 674.74 COORDINATE GAS, CTV AND ELECTRIC SAN MH 4 RIM 680.00 6" AWWA C-900 PVC WATER UTILITY LOCATION AND SIZE WITH UE 6"x4" REDUCER INV 672.48 E MAIN (MIN. 5' COVER) 6"-45° BEND UTILITY COMPANIES AND MEP DRAWINGS 8"x6" WYE 6"x6"x4" TEE 8"x6" WYE PARKING 4"-45° BENDS INV 672.62 INV 672.10 LOT UE HYDRANT ASSEMBLY UE 11 LF 6" SDR-35 PVC SANITARY STOP 11 LF 6" SDR-35 PVC SANITARY SAN MH 3 PART OF 4" GATE VALE SEWER LATERAL @ 1.0% MIN. SEWER LATERAL @ 1.0% MIN. RIM 686.00 146°-28'-21" 4" GATE VALE INV 671.50 W L-11442, P-836 UE INSTALL C.O., TRAP AND INV 671.40 NE VENT IN GREENSPACE INSTALL C.O., TRAP AND Multifamily Development VENT IN GREENSPACE INV 673.80 246 LF 8" SDR-35 REDUCE TO 2" INV 673.30 UE PVC PRIVATE SAN REDUCE TO 2" DOMESTIC SERVICE SEWER @ 0.4% DOMESTIC SERVICE INSIDE BUILDING INSIDE BUILDING UE PROPOSED 1-STORY 6 UNIT BUILDING #6 UE PROPOSED 1-STORY 6 UNIT BUILDING #5 W/ATTACHED GARAGES 149°-26'-50" W/ATTACHED GARAGES UE F.F.E. = 682.80 F.F.E. = 682.80 1425 & 1475 Orchard Park Rd PARKING UE LOT UE SCRUB SHRUB WETLANDS (PSS) © CARMINA WOOD DESIGN (APPROXIMATE LOCATION) West Seneca, NY 153°-18'-56" UE 8" UE UE UE 6/17/26 Date UE UE Per Engineering comments 8" 12" 11" 6" 8" No. Description 7" 12" 6" REVISIONS: 6" 6" 12" 13" 1 6" 133°-32'-58" PROPOSED UTILITY LEGEND PROPOSED STORM SEWER ST Utility Plan - South PROPOSED SANITARY SEWER 6" SA UTILITY NOTES: NOTES: SCALE: 1"=30' 1" W PROPOSED WATERLINE 1. FOR ALL SANITARY SEWERS, INSTALL SELECT FILL IN PAVED AREAS, EXTEND 5' MIN. BEYOND PAVEMENT LIMITS 1. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORMTOWNTOOF WEST SENECA SEWER SPECIFICATIONS AND DETAILS, AND ERIE COUNTY DEPARTMENT OF HEALTH RULES AND 2. BUILDINGS TO HAVE6"AHOUSE TRAP, VENT AND CLEANOUT INSTALLED AT ENTRANCE POINT. INVERT ELEVATION REGULATIONS. TO BE5' MIN.BELOW F.F.E. OF THE BUILDING. PIPE TO 6" SDR-35 BE PVC @ 1.0% MIN WITH MIN 4' OF COVER. ADD PROPOSED CATCH BASIN CB ADDITIONAL CLEANOUTS @ 100' MAX. SPACING 6" LATERALS FOR OVER 90' IN LENGTH. 2. PRIOR STARTING ANY WORK ASSOCIATED WITH OR NEAR EXISTING SANITARY MANHOLES, THE CONTRACTOR SHALL MEET WITHTOWN THE OF WEST SENECA TO DISCUSS AND AGREE DRAWING NAME: 3. COORDINATE GAS & ELEC. METER BANK LOCATIONS ON BUILDINGS WITH M.E.P. PLANS & UTILITY CO.'S. TO THE WORK. PROPOSED YARD DRAIN YD 4. COORDINATE LOCATION OF CTV & TELEPHONE SERVICE TO BUILDINGS WITH M.E.P. PLANS AND UTILITY CO.'S. 3. FILL SHALL BE PLACED AND SATISFACTORILY COMPACTED PRIOR TO INSTALLATION OF Utility Plan - South UTILITIES, AND MUST BE APPROVED BY THE SUPERVISING PROJECT ENGINEER. PROPOSED MANHOLE MH 5. ANY EXISTING UTILITIES WHICH ARE TO BE ABANDONED AND FALL UNDER PAVEMENT OR BUILDINGS SHALL BE REMOVED VS. BEING ABANDONED UNLESS THOSE UTILITIES ARE FILLED WITH FLOWABLE FILL. 4. ALL OTHER REQUIRED PERMITS BY THE STATE OF NEW YORK, COUNTY OFTOWN ERIE AND PROPOSED HYDRANT ASSEMBLY OF WEST SENECA ARE THE RESPONSIBILITY OF THE CONTRACTOR/DEVELOPER. 6. EXISTING GAS SERVICES TO REMAIN UNLESS OTHERWISE NOTED. ANY PORTIONS TO BE RELOCATED SHALL BE COORDINATED WITH NATIONAL FUEL GAS. PROPOSED GATE VALVE GV Date: 5/22/26 7. ALL UNDERGROUND TELEPHONE SERVICES SHALL REMAIN AND BE PROTECTED DURING CONSTRUCTION. NOTE: FOR PROPOSED VALVE BOXES, CLEANOUTS, ETC., INSTALL A Drawn By: A. Pandolfe 3,000 PSI CONCRETE COLLAR AROUND THE ITEM AT GRADE. THE 8. A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES OF VERTICAL SEPARATION MUST BE MAINTAINED BETWEEN ALL COLLAR SHALL BE A MINIMUM OF 6" WIDER, ON ALL SIDES, THAN THE Scale: As Noted SANITARY SEWER AND WATER SERVICES. BOX, CLEANOUT, ETC. THE COLLAR SHALL BE A MINIMUM OF 6" THICK. DRAWING NO. 9. ERIE COUNTY WATER AUTHORITY (ECWA) IS TO BE NOTIFIED A MINIMUM OF 48-HOURS PRIOR TO STARTING THE CONNECTION TO THE NEW WATER SERVICE. 10. SELECT BACKFILL IS REQUIRED FOR ALL UTILITIES (GAS, WATER, STORM, SANITARY) THAT CROSS THROUGH PAVEMENT AREAS. NOTE: BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY OTHERS, CARMINA WOOD DESIGN ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY. 30 0 30 60Ft. C-402 Project No: 23-4121 30' Page 1154 of 1493