PART 8 General Development Standards  91 OF 148

  xi.  Plan for ingress and egress to the  g. Turbine drawings: must contain
  proposed project site, including:  photographs or detailed drawings of each
  wind turbine model, including the tower
  (A) A description of the access route
  and foundation.
  from the nearest state, county,
  and/or City-maintained roads to  h. Noise report. A noise report shall be
  include:  furnished which shall include the
  following:
  (1) Road surface material,
  stating the type and amount  i.  A description and map of the projects
  of surface cover.  noise-producing features, including
  (2) Width and length of access  the range of noise levels expected,
  route.  and the tonal and frequency
  characteristics expected. The noise
  (3) Dust control procedures.  report shall include low frequency,
  (B) A road maintenance schedule or  infrasound, pure tone, and repetitive/
  program.  impulsive sound.

  (C) Review of railroad accessibility  ii.  A description and map of the noise-
  for deliveries.  sensitive environment, including
  any sensitive noise receptors (i.e.,
  xii. Detailed construction plan, including
  residences, hospitals, libraries,
  but not limited to a construction
  schools, places of worship and other
  schedule; hours of operation;
  facilities where quiet is important)
  designation of heavy haul routes; a
  within two miles of the proposed
  list of material equipment and loads
  facilities.
  to be transported; identification
  of temporary facilities intended  iii. A survey and report prepared by
  to be constructed; and a contact  a qualified engineer that analyzes
  representative in the field with a  the preexisting ambient noise
  name and phone number.  regime, including seasonal variation,
  including but not limited to separate
  xiii. Tree removal. All groves of trees shall
  measurements of low frequency and
  be located on the site plan at the time
  A-weighted noise levels across a
  of application. No grove or woodlots
  range of wind speeds, including near
  of trees shall be removed without
  cut-in, turbulence measurements,
  approval of the Planning Board,
  distance from the turbines, location
  excluding the BRA area.
  of sensitive receptors relative to wind
f. Turbine information: must contain  direction and analyses at affected
  specific information on the type, size,  sensitive receptors, located within
  height, rotor material, rated power  two miles of the proposed project
  output, performance, safety, and noise  site.
  characteristics of each commercial wind
  turbine model, tower, and electrical
  transmission equipment.