Text · page 135 of 219
Read the whole document on one page (all 219 pages, each with its own heading)
112 OF 148 CITY OF LACKAWANNA • NY 2026 ZONING ORDINANCE | Chapter 300: Zoning g. To provide that developers are notified Base Flood. The flood having a one-percent chance that property is in an area of special flood of being equaled or exceeded in any given year. hazard; and Basement. That portion of a building having its floor h. To ensure that those who occupy the subgrade (below ground level) on all sides. areas of special flood hazard assume responsibility for their actions. Breakaway Wall. A wall that is not part of the structural support of the building and is intended B. Definitions. Unless specifically defined below, through its design and construction to collapse words or phrases used in this section shall be under specific lateral loading forces without causing interpreted so as to give them the meaning they damage to the elevated portion of the building or the have in common usage and to give this section supporting foundation system. its most reasonable application. Building. See "structure." 100-Year Flood. Has the same meaning as "base flood." Cellar. Has the same meaning as "basement." Accessory Structure. A structure used solely for Coastal A Zone. Area within a SFHA, landward of a parking (two-car detached garages or smaller) or V1-V30, VE, or V Zone or landward of an open coast limited storage, represents a minimal investment without mapped coastal high hazard areas. In a of not more than 10% of the value of the primary Coastal A Zone, the principal source of flood must be structure, and may not be used for human habitation. astronomical tides, storm surges, seiches or tsunamis, not riverine flooding. During the base flood conditions, Appeal. A request for a review of the local the potential for breaking wave height shall be greater administrator's interpretation of any provision of this than or equal to 1 1/2 feet (457 mm). The inland limit section or a request for a variance. of Coastal A Zone is: a) the limit of moderate wave Area of Shallow Flooding. A designated AO, AH or action if delineated on a FIRM; or b) designated by the VO Zone on a community's FIRM with a one-percent- authority having jurisdiction. or-greater annual chance of flooding to an average Coastal High Hazard Area. An area of special flood annual depth of one foot to three feet where a clearly hazard extending from offshore to the inland limit of defined channel does not exist, where the path of a primary frontal dune along an open coast and any flooding is unpredictable and where velocity flow may other area subject to high velocity wave action from be evident. Such flooding is characterized by ponding storms or seismic sources. The area is designated on or sheet flow. a FIRM as Zone V1-V30, VE, VO or V. Area Of Special Flood Hazard. The land in the Crawl Space. An enclosed area beneath the lowest floodplain within a community subject to a one- elevated floor, 18 inches or more in height, which percent-or-greater chance of flooding in any given is used to service the underside of the lowest year. This area may be designated as Zone A, AE, elevated floor. The elevation of the floor of this AH, AO, A1-A30, A99, V, VO, VE, or V1-V30. It is also enclosed area, which may be of soil, gravel, concrete commonly referred to as the base floodplain or 100- or other material, must be equal to or above the year floodplain. For purposes of this section, the term lowest adjacent exterior grade. The enclosed crawl "special flood hazard area (SFHA)" is synonymous space area shall be properly vented to allow for the in meaning with the phrase "area of special flood equalization of hydrostatic forces which would be hazard." experienced during periods of flooding.