PART 11 Permit and Site Plan Procedures;Enforcement and Penalties  125 OF 148

  (1) A minimum of two openings  (B) Utilities.
  of each enclosed area  (1) New and replacement
  having a total net area of  electrical equipment,
  not less than one square  heating, ventilating, air
  inch for every square foot  conditioning, plumbing
  of enclosed area subject to  connections, and other
  flooding;  service equipment shall
  (2) The bottom of all such  be located at least two
  openings no higher than one  feet above the base flood
  foot above grade; and  elevation, or be designed to
  (3) Openings not less than three  prevent water from entering
  inches in any direction.  and accumulating within the
  components during a flood
  (B) Openings may be equipped with  and to resist hydrostatic
  louvers, valves, screens or other  and hydrodynamic loads
  coverings or devices provided  and stresses. Electrical
  they permit the automatic entry  wiring and outlets, switches,
  and exit of floodwaters. Enclosed  junction boxes and
  areas subgrade on all sides are  panels shall be elevated
  considered basements and are  or designed to prevent
  not permitted.  water from entering and
iv. Within Zones V1-V30 and VE,  accumulating within the
  and also within Zone V if base  components unless they
  flood elevation are available, new  conform to the appropriate
  construction and substantial  provisions of the electrical
  improvements shall have the space  part of the Building Code
  below the lowest floor either free  of New York State or the
  from obstruction or constructed with  Residential Code of New
  nonsupporting breakaway walls,  York State for location of
  open wood lattice-work or insect  such items in wet locations;
  screening intended to collapse  [Amended 6-29-2021]
  under wind and water loads without  (2) New and replacement
  causing collapse, displacement,  water supply systems shall
  or other structural damage to the  be designed to minimize
  elevated portion of the building  or eliminate infiltration of
  or supporting foundation system.  floodwaters into the system;
  The enclosed space below the
  lowest floor shall be used only for
  parking vehicles, building access or
  storage. Use of this space for human
  habitation is expressly prohibited.
  The construction of stairs, stairwells
  and elevator shafts are subject to the
  design requirements for breakaway
  walls.