Text · page 156 of 219
Read the whole document on one page (all 219 pages, each with its own heading)
PART 11 Permit and Site Plan Procedures;Enforcement and Penalties 133 OF 148 a. Recreational vehicles. e. Within V or VE, manufactured homes must meet the requirements of i. Recreational vehicles placed on sites Subsection E(4). within Zones A, A1-A30, AE, AH, AO, V1-V30, V, and VE shall either: 8. Accessory structures, including detached garages. The following standards apply to (A) Be on site fewer than 180 new and substantially improved accessory consecutive days; structures, including detached garages, in (B) Be fully licensed and ready for the areas of special flood hazard shown on highway use; or the Flood Insurance Rate Map designated in (C) Meet the requirements for Subsection C(2). manufactured homes in a. Within Zones A1-A30, AE, AO, AH, Subsection E(7)(b), (c) and (d). A, accessory structures must meet ii. A recreational vehicle is ready for the standards of Subsection E(2)(a), highway use if it is on its wheels or Anchoring. jacking system, is attached to the site b. Within Zones A1-A30, AE and AH, and also only by quick disconnect type utilities Zone A if base flood elevation data are and security devices and has no available, areas below two feet above the permanently attached additions. base flood elevation shall be constructed b. A manufactured home that is placed using methods and practices that or substantially improved in Zones minimize flood damage. A1-A30, AE, and AH shall be elevated on c. Within Zones AO and Zone A, if base a permanent foundation such that the flood elevation data are not available, bottom of the frame of the manufactured areas below three feet above the highest home chassis is elevated to or above two adjacent grade shall be constructed using feet above the base flood elevation and methods and practices that minimize is securely anchored to an adequately flood damage. anchored foundation system to resist d. Structures must be designed to flotation, collapse and lateral movement. automatically equalize hydrostatic flood Elevation on piers consisting of dry forces on exterior walls by allowing stacked blocks is prohibited. for the entry and exit of floodwaters in c. Within Zone A, the bottom of the frame of accordance with Subsection E(2)(c), the manufactured home shall be elevated Utilities. to meet the requirements of Subsection e. Within Zones V1-V30, VE, and V, E(3)(a)[2]. [Amended 6-29-2021] accessory structures (unless properly d. Within Zone AO, the bottom of the frame elevated to the base flood elevation plus of the manufactured home chassis shall two feet on piles or columns) must be be elevated above the highest adjacent limited to small, low-value structures that grade at least as high as the depth are disposable. If a community wishes to number specified on the Flood Insurance allow unelevated accessory buildings, it Rate Map enumerated in Subsection must define "small" and "low cost." C(2) plus two feet (at least three feet if no f. Within Zones V1-V30, VE, and V, depth number is specified). Elevation on unelevated accessory buildings must piers consisting of dry stacked blocks is be unfinished inside, constructed with prohibited. flood-resistant materials, and used only for storage.