Text · page 155 of 219
Read the whole document on one page (all 219 pages, each with its own heading)
132 OF 148 CITY OF LACKAWANNA • NY 2026 ZONING ORDINANCE | Chapter 300: Zoning a. Within Zones A1-A30, AE and AH, and c. If the structure is to be floodproofed, also Zone A if base flood elevation a licensed professional engineer or data are available, new construction architect shall develop and/or review and substantial improvements of any structural design, specifications, and nonresidential structure, together with plans for construction. A floodproofing attendant utility and sanitary facilities, certificate or other certification shall shall either: be provided to the local administrator that certifies the design and methods i. Have the lowest floor, including of construction are in accordance with basement or cellar, elevated to or accepted standards of practice for above two feet above the base flood meeting the provisions of Subsection E(5) elevation; or, (a)[2], including the specific elevation (in ii. Be floodproofed so that the structure relation to mean sea level) to which the is watertight below two feet above structure is to be floodproofed. the base flood elevation, including d. Within Zones AH and AO, adequate attendant utility and sanitary facilities, drainage paths are required to guide with walls substantially impermeable floodwaters around and away from to the passage of water. All structural proposed structures on slopes. components located below the base flood elevation must be e. Within Zone A, when no base flood capable of resisting hydrostatic and elevation data are available, the lowest hydrodynamic loads and the effects floor (including basement) shall be of buoyancy. elevated at least three feet above the highest adjacent grade. b. Within Zone AO, new construction and substantial improvements of 6. Nonresidential structures (coastal high nonresidential structures shall: hazard areas and Coastal A Zones). In Zones V1-V30, VE and also Zone V if base flood i. Have the lowest floor (including elevations are available, new construction basement) elevated above the and substantial improvements of any highest adjacent grade at least as nonresidential structure, together with high as the depth number specified attendant utility and sanitary facilities, shall in feet on the community's FIRM have the bottom of lowest member of the plus two feet (at least three feet if no lowest floor elevated to or above two feet depth number is specified); or above the base flood elevation. Floodproofing ii. Together with attendant utility and of structures is not an allowable alternative to sanitary facilities, be completely elevating the lowest floor to two feet above floodproofed to that level to meet the the base flood elevation in Zones V1-V30, VE floodproofing standard specified in and V. Subsection E(5)(a)[2]. 7. Manufactured homes and recreational vehicles. The following standards in addition to the standards in Subsections E(1), General standards, and E(2), Standards for all structures, apply, as indicated, in areas of special flood hazard to manufactured homes and to recreational vehicles which are located in areas of special flood hazard.