Text · page 1065 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration. CURRENT All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145 Greensboro SHEET (DESIGNED BY OTHERS) (SHEET C-401) (SHEET C-403) Utica SHEET LOCATION MAP Buffalo S T SCALE: N.T.S. OP OP ST West Seneca Exchange APPROXIMATE LOCATION OF EXISTING 6" SDR-35 PVC SANITARY LATERAL FROM TOPS FUT MARKETS TO REMAIN AND BE REUSED; URE Slade Ave, Ridge Rd & Orchard Park Rd COORDINATE CONNECTION WITH TOPS 1 MARKETS TO ENSURE UNINTERRUPTED SERVICE DURING CONSTRUCTION 80,3 -STOR SAN MH 7 00 S Y RE P O RIM 613.93 ST PROPOSED PIPE CROSSING: S INV 604.71 NW INV 604.61 PROPOSED HYDRANT ASSEMBLY TO BE INSTALLED WITHIN FUTURE CURBED ISLAND AS SHOWN .F. TAIL 620 10" SAN. INV=604.50 DN 42" STORM INV=606.58 West Seneca New York 170 LF 10" SDR-35 PVC @ 1.76% APPROXIMATE LOCATION OF FUTURE SANITARY © CARMINA WOOD DESIGN PROPOSED 8" SDR-35 PVC SANITARY LATERAL FROM PROPOSED BUILDING; TO BE INSTALLED 0 DURING FUTURE PHASE OF CONSTRUCTION 62 189 LF LATERAL FROM EX. SANITARY 10" SDR-35 MANHOLE; COORDINATE PVC @ 0.40% CONNECTION WITH TOPS MARKETS APPROXIMATE LOCATION OF EXISTING TO ENSURE UNINTERRUPTED SERVICE TO BE REUSED FUTURE WATER SERVICE DURING CONSTRUCTION TO PROPOSED BUILDING; TO BE REUSED FOR FUTURE PHASE OF CONSTRUCTION WV SAN MH 6 MAINTAIN 18" VERTICAL RIM 615.81 CLEARING AT ALL PROPOSED HYDRANT ASSEMBLY SE INV 603.85 STORM/SANITARY CROSSINGS, TO BE INSTALLED WITHIN FUTURE NW INV 603.75 TYP. CURBED ISLAND AS SHOWN PROVIDE BENDS & EXISTING WATERMAIN TO REMAIN & BE Date BLOCKING AS CONTRACTOR TO INSTALL REUSED WITHIN SITE. ALL EXISTING ST REQUIRED PROPOSED 10" G.V. AT TENANTS SHALL HAVE CONSTANT, CONNECTION TO EX. 10" UNINTERRUPTED WATER SERVICE DURING ST WATERMAIN CONSTRUCTION ST RS) PROPOSED 10" GATE ST VALVE E ST PROPOSED OTH W 10" GATE PROP. 6" AWWA C-900 APPROXIMATE LOCATION OF FUTURE SANITARY LATERAL FROM PROPOSED -B W 76 VALVE PVC COMBINED SERVICE PROPOSED 10" AWWA BUILDING; TO BE INSTALLED DURING FUTURE PHASE OF CONSTRUCTION -B Y -BW 76 ST NS B PROPOSED (5' MIN. COVER) PROPOSED C-900 PVC COMBINED ST -BW 2) 76 PROPOSED 10" AWWA STOP No. Description 10" GATE 10"x10"x6" WATER SERVICE (5' ST 0 76 C-900 PVC COMBINED S TOP (PLA (C-4 PROPOSED VALVE TEE MIN. COVER) ST WATER SERVICE (5' REVISIONS: ST MIN. COVER) 10"x10"x10" TEE ST PROPOSED 6" INE INE 227 LF GATE VALVE PROPOSED ST CHL 10" GATE CHL 10" SDR-35 ST PVC @ 0.40% VALVE CONTRACTOR TO INSTALL PROPOSED 6" APPROXIMATE LOCATION OF FUTURE MAT G.V. AT CONNECTION TO EX. 6" WATERMAIN MAT ST SANITARY LATERAL FROM PROPOSED ST BUILDING; TO BE INSTALLED DURING MATCHLINE (C-402) ST FUTURE PHASE OF CONSTRUCTION PROPOSED 6" GATE VALVE PROP. CAP TO BE INSTALLED PROPOSED 10" AWWA C-900 PVC ST MATCHLINE (C-401) JUST AFTER 6" GATE VALVE AS COMBINED WATER SERVICE (5' MIN. COVER) IO APPROXIMATE LOCATION OF FUTURE PROPOSED 10"x10"x8" TEE ST SHOWN (FOR FUTURE USE) ST PAT WATER SERVICE TO PROPOSED PROPOSED PIPE CROSSING: BUILDING; TO BE INSTALLED DURING FUT PROPOSED 10" GATE VALVE ST 10" SAN. INV=603.00 48" STORM INV=605.05 ST FUTURE PHASE OF CONSTRUCTION URE PROPOSED ST CONTRACTOR TO INSTALL PROPOSED 10" G.V. 130 RETA PROPOSED 10" GATE STOP ST VALVE AT CONNECTION TO EX. 10" WATERMAIN ST ST 9,10 'x70' IL PROPOSED 10" GATE VALVE STOP 10" GATE Sealed 07/20/2026 VALVE ST FU 0 SF 10"x10"x6" EXISTING WATERMAIN TO REMAIN & BE REUSED RESTTURE D ST ST PROPOSED MAINTAIN 18" VERTICAL WITHIN SITE. ALL EXISTING TENANTS SHALL ST STOP TEE AUR RIVE- ST ST CLEARING AT ALL HAVE CONSTANT, UNINTERRUPTED WATER WV ANT THR STORM/SANITARY SERVICE DURING CONSTRUCTION IO ST ST CONTRACTOR TO4INSTALL U ST CROSSINGS, TYP. CA ,963 PROPOSED PROPOSED UTILITY LEGEND PAT UT 10" G.V. IO ST ST SFWATERMAIN N STOP AT CONNECTION TO EX. 10" PROPOSED 10" GATE VALVE TO BE PROPOSED PIPE CROSSING: PROP. 6" AWWA C-900 PVC PROP. 8" INSTALLED ON EX. 10" WATER SERVICE PROPOSED STORM SEWER ST N IO ST UT 8" SAN. INV=603.15 ST GATE VALVE CA COMBINED SERVICE (5' MIN. COVER) STOP AS SHOWN FOR FUTURE CONNECTION SAN MH 5 48" STORM INV=605.56 STOP ST 6" SA ST ST S SAN MH 12 PROPOSED PIPE CROSSING:TOP ST RIM 613.81 PROPOSED SANITARY SEWER ST ST ST RIM 616.78 ST SE INV 602.84 OP PROPOSED 8" AWWA C-900 PVC COMBINED ST 8" SAN. INV=603.13 PROPOSED 6" WATER SERVICE (5' MIN. COVER) NW INV 607.33 SW INV 602.84 ST ST GATE VALVE NW INV 602.74 24" STORM INV=608.20 PROPOSED WATERLINE 1" W ST ST APPROXIMATE LOCATION OF PROP. CAP TO BE PROP. CAP TO BE INSTALLED ST ST ST FUTURE WATER SERVICE TO ST ST CA ST JUST AFTER 6" GATE VALVE AS INSTALLED JUST UT ST PROPOSED BUILDING; TO BE FUT 200 LF IO ST 396 LF SHOWN (FOR FUTURE USE) AFTER 10" GATE PROPOSED CATCH BASIN CB N ST ST ST INSTALLED DURING FUTURE DRAWING NAME: 2,50 URE 10" SDR-35 ST APPROXIMATE LOCATION OF FUTURE 8" SDR-35 VALVE AS SHOWN ST ST PROPOSED PHASE OF CONSTRUCTION N ST ST IO PVC @ 0.40% ST PVC @ 0.40% (FOR FUTURE USE) UT 0 G. Utility Plan ST SANITARY LATERAL FROM PROPOSED ST 8"x8"x6" TEE CA STOP ST APPROXIMATE LOCATION OF FUTURE PROPOSED YARD DRAIN YD FUTSANITARY LATERAL FROM PROPOSED ST BAN S.F. BUILDING; TO BE INSTALLED DURING ST FUTURE PHASE OF CONSTRUCTION ST URE TO BE INSTALLED DURING RES BUILDING; ST ST K ST ST ST ST TAFUTUREDRIV OF CONSTRUCTION OFFSITE IMPROVEMENTS TO ST U PHASE E RAN CONNECT TO EXISTING SAN PROPOSED MANHOLE MH ST T 2, -THRU ST ST ST MANHOLE 12 AT INV. 607.43. WV ST ST 380 STOP ST ST STOP REFER TO PLANS BY OTHERS. ST ST ST SF PROPOSED HYDRANT ASSEMBLY ST ST OR TO PLUG ST STOP Date: 07/20/26 ST AST INVERT; ST APPROXIMATE LOCATION OF FUTURE ST PROPOSED GATE VALVE GV ST DEMOLITION PLAN PROPOSED 8" AWWA C-900 STOP APPROXIMATE LOCATION OF FUTURE SANITARY LATERAL FROM PROPOSED ST ST Drawn By: C. Wood SANITARY LATERAL FROM PROPOSED BUILDING; TO BE INSTALLED DURING PVC COMBINED WATER Scale: As Noted SAN MH 3 STOP STOP ST SERVICE (5' MIN. COVER) NOTE: FOR PROPOSED VALVE BOXES, CLEANOUTS, ETC., INSTALL A ST BUILDING; TO BE INSTALLED DURING FUTURE PHASE OF CONSTRUCTION ST IM 614.36 STOP ST 3,000 PSI CONCRETE COLLAR AROUND THE ITEM AT GRADE. THE DRAWING NO. FUTURE PHASE OF CONSTRUCTION SAN MH 4 SAN MH 8 ST COLLAR SHALL BE A MINIMUM OF 6" WIDER, ON ALL SIDES, THAN THE ST NV 601.31 RIM 612.66 UTILITY PLAN ST ST RIM 613.96 BOX, CLEANOUT, ETC. THE COLLAR SHALL BE A MINIMUM OF 6" THICK. C-402 ST NV 601.21 SE INV 601.94 FU MAINTAIN 18" VERTICAL CLEARING AT ST RES TURE D STOP ST SW INV 604.52 ST ALL STORM/SANITARY CROSSINGS, TYP. N INV 601.84 ST TAU RIV NE INV 604.42 STOP ST NOTE: BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY OTHERS, ST ST ST RAN E-TH SCALE: 1"=40' CARMINA WOOD DESIGN ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY. ST 133 LF T, 2 RU ST ,300 PROPOSED PIPE CROSSING: ST ST 10" SDR-35 Project No: 24-4113 ST ST ST SF 8" SAN. INV= 604.55 40 0 40 80Ft. ST PVC @ 0.40% ST 24" STORM INV=609.25 209 LF 40' PROPOSED PIPE CROSSING: PROPOSED PIPE CROSSING: 8" SDR-35 Page 1065 of 1174 ST 10" SAN. INV=601.18 ST ST ST