Southtowns Record

PB Agenda Packet 8.13.2026

Government
Town of West Seneca
Board
Planning Board
Meeting
Aug 13, 2026, 6:00 p.m.
Posted by publisher
Jul 28, 2026
Kind
Agenda packet
Topics
Water, sewer and drainage, Roads and traffic, Housing, Zoning and land use, Parks and recreation, Budget and taxes, Public safety

Original document

Same meeting

Text · page 1065 of 1174

Read the whole document on one page (all 1174 pages, each with its own heading)

sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor
  to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration.

  CURRENT
  All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145

  Greensboro
  SHEET
  (DESIGNED
  BY OTHERS)
  (SHEET C-401)

  (SHEET C-403)

  Utica
  SHEET LOCATION MAP

  Buffalo
  S T
  SCALE: N.T.S.

  OP

  OP
  ST

  West Seneca Exchange
  APPROXIMATE LOCATION OF EXISTING 6"
  SDR-35 PVC SANITARY LATERAL FROM TOPS  FUT
  MARKETS TO REMAIN AND BE REUSED;  URE

  Slade Ave, Ridge Rd & Orchard Park Rd
  COORDINATE CONNECTION WITH TOPS
  1
  MARKETS TO ENSURE UNINTERRUPTED
  SERVICE DURING CONSTRUCTION  80,3 -STOR
  SAN MH 7
  00 S Y RE
  P  O
  RIM 613.93  ST
  PROPOSED PIPE CROSSING:
  S INV 604.71
  NW INV 604.61
  PROPOSED HYDRANT ASSEMBLY
  TO BE INSTALLED WITHIN FUTURE
  CURBED ISLAND AS SHOWN
  .F. TAIL  620

  10" SAN. INV=604.50  DN

  42" STORM INV=606.58

  West Seneca New York
  170 LF
  10" SDR-35
  PVC @ 1.76%  APPROXIMATE LOCATION OF FUTURE SANITARY
  © CARMINA WOOD DESIGN

  PROPOSED 8" SDR-35 PVC SANITARY  LATERAL FROM PROPOSED BUILDING; TO BE INSTALLED

  0
  DURING FUTURE PHASE OF CONSTRUCTION

  62
  189 LF  LATERAL FROM EX. SANITARY
  10" SDR-35  MANHOLE; COORDINATE
  PVC @ 0.40%  CONNECTION WITH TOPS MARKETS  APPROXIMATE LOCATION OF EXISTING
  TO ENSURE UNINTERRUPTED SERVICE  TO BE REUSED FUTURE WATER SERVICE
  DURING CONSTRUCTION  TO PROPOSED BUILDING; TO BE REUSED
  FOR FUTURE PHASE OF CONSTRUCTION

  WV

  SAN MH 6  MAINTAIN 18" VERTICAL
  RIM 615.81  CLEARING AT ALL  PROPOSED HYDRANT ASSEMBLY
  SE INV 603.85  STORM/SANITARY CROSSINGS,  TO BE INSTALLED WITHIN FUTURE
  NW INV 603.75  TYP.  CURBED ISLAND AS SHOWN
  PROVIDE BENDS &  EXISTING WATERMAIN TO REMAIN & BE

  Date
  BLOCKING AS  CONTRACTOR TO INSTALL  REUSED WITHIN SITE. ALL EXISTING  ST
  REQUIRED  PROPOSED 10" G.V. AT  TENANTS SHALL HAVE CONSTANT,
  CONNECTION TO EX. 10"  UNINTERRUPTED WATER SERVICE DURING  ST
  WATERMAIN  CONSTRUCTION  ST

  RS)
  PROPOSED 10" GATE  ST
  VALVE

  E
  ST
  PROPOSED

  OTH

  W
  10" GATE  PROP. 6" AWWA C-900  APPROXIMATE LOCATION OF FUTURE SANITARY LATERAL FROM PROPOSED

  -B

  W
  76
  VALVE  PVC COMBINED SERVICE  PROPOSED 10" AWWA  BUILDING; TO BE INSTALLED DURING FUTURE PHASE OF CONSTRUCTION

  -B
  Y

  -BW
  76
  ST

  NS B
  PROPOSED  (5' MIN. COVER)  PROPOSED  C-900 PVC COMBINED

  ST

  -BW
  2)

  76
  PROPOSED 10" AWWA  STOP

  No. Description
  10" GATE  10"x10"x6"  WATER SERVICE (5'  ST

  0

  76
  C-900 PVC COMBINED  S  TOP

  (PLA
  (C-4
  PROPOSED  VALVE  TEE  MIN. COVER)  ST
  WATER SERVICE (5'

  REVISIONS:
  ST
  MIN. COVER)  10"x10"x10" TEE  ST
  PROPOSED 6"

  INE
  INE
  227 LF  GATE VALVE  PROPOSED  ST

  CHL
  10" GATE

  CHL
  10" SDR-35

  ST
  PVC @ 0.40%  VALVE  CONTRACTOR TO INSTALL PROPOSED 6"
  APPROXIMATE LOCATION OF FUTURE

  MAT
  G.V. AT CONNECTION TO EX. 6" WATERMAIN

  MAT
  ST  SANITARY LATERAL FROM PROPOSED

  ST
  BUILDING; TO BE INSTALLED DURING
  MATCHLINE (C-402)  ST
  FUTURE PHASE OF CONSTRUCTION  PROPOSED 6"
  GATE VALVE
  PROP. CAP TO BE INSTALLED  PROPOSED 10" AWWA C-900 PVC

  ST
  MATCHLINE (C-401)  JUST AFTER 6" GATE VALVE AS  COMBINED WATER SERVICE (5' MIN. COVER)
  IO

  APPROXIMATE LOCATION OF FUTURE  PROPOSED 10"x10"x8" TEE
  ST  SHOWN (FOR FUTURE USE)
  ST

  PAT

  WATER SERVICE TO PROPOSED
  PROPOSED PIPE CROSSING:  BUILDING; TO BE INSTALLED DURING  FUT  PROPOSED 10" GATE VALVE

  ST
  10" SAN. INV=603.00
  48" STORM INV=605.05
  ST
  FUTURE PHASE OF CONSTRUCTION  URE  PROPOSED
  ST

  CONTRACTOR TO INSTALL PROPOSED 10" G.V.
  130 RETA  PROPOSED  10" GATE
  STOP ST
  VALVE  AT CONNECTION TO EX. 10" WATERMAIN

  ST
  ST

  9,10 'x70' IL
  PROPOSED 10" GATE VALVE  STOP  10" GATE

  Sealed 07/20/2026
  VALVE
  ST

  FU  0 SF 10"x10"x6"  EXISTING WATERMAIN TO REMAIN & BE REUSED
  RESTTURE D
  ST
  ST

  PROPOSED  MAINTAIN 18" VERTICAL  WITHIN SITE. ALL EXISTING TENANTS SHALL

  ST
  STOP

  TEE
  AUR RIVE-  ST
  ST  CLEARING AT ALL  HAVE CONSTANT, UNINTERRUPTED WATER  WV
  ANT THR  STORM/SANITARY  SERVICE DURING CONSTRUCTION
  IO
  ST

  ST
  CONTRACTOR TO4INSTALL  U
  ST
  CROSSINGS, TYP.

  CA
  ,963 PROPOSED  PROPOSED UTILITY LEGEND
  PAT

  UT
  10" G.V.

  IO
  ST  ST
  SFWATERMAIN

  N
  STOP

  AT CONNECTION TO EX. 10"  PROPOSED 10" GATE VALVE TO BE
  PROPOSED PIPE CROSSING:  PROP. 6" AWWA C-900 PVC  PROP. 8"  INSTALLED ON EX. 10" WATER SERVICE  PROPOSED STORM SEWER  ST

  N
  IO
  ST

  UT
  8" SAN. INV=603.15  ST  GATE VALVE

  CA
  COMBINED SERVICE (5' MIN. COVER)  STOP  AS SHOWN FOR FUTURE CONNECTION
  SAN MH 5  48" STORM INV=605.56
  STOP  ST
  6" SA
  ST

  ST
  S  SAN MH 12
  PROPOSED PIPE CROSSING:TOP ST
  RIM 613.81  PROPOSED SANITARY SEWER
  ST

  ST  ST  RIM 616.78
  ST

  SE INV 602.84  OP  PROPOSED 8" AWWA C-900 PVC COMBINED
  ST

  8" SAN. INV=603.13  PROPOSED 6"  WATER SERVICE (5' MIN. COVER)  NW INV 607.33
  SW INV 602.84  ST  ST
  GATE VALVE
  NW INV 602.74
  24" STORM INV=608.20  PROPOSED WATERLINE  1" W
  ST

  ST  APPROXIMATE LOCATION OF  PROP. CAP TO BE
  PROP. CAP TO BE INSTALLED  ST
  ST

  ST

  FUTURE WATER SERVICE TO
  ST

  ST

  CA
  ST  JUST AFTER 6" GATE VALVE AS  INSTALLED JUST

  UT
  ST
  PROPOSED BUILDING; TO BE
  FUT  200 LF

  IO
  ST

  396 LF  SHOWN (FOR FUTURE USE)  AFTER 10" GATE  PROPOSED CATCH BASIN  CB

  N
  ST
  ST

  ST  INSTALLED DURING FUTURE  DRAWING NAME:
  2,50 URE  10" SDR-35  ST
  APPROXIMATE LOCATION OF FUTURE  8" SDR-35  VALVE AS SHOWN
  ST

  ST

  PROPOSED  PHASE OF CONSTRUCTION

  N
  ST

  ST

  IO
  PVC @ 0.40%  ST
  PVC @ 0.40%  (FOR FUTURE USE)

  UT
  0 G.  Utility Plan
  ST

  SANITARY LATERAL FROM PROPOSED  ST
  8"x8"x6" TEE

  CA
  STOP  ST  APPROXIMATE LOCATION OF FUTURE  PROPOSED YARD DRAIN  YD
  FUTSANITARY LATERAL FROM PROPOSED
  ST

  BAN S.F.  BUILDING; TO BE INSTALLED DURING  ST
  FUTURE PHASE OF CONSTRUCTION  ST  URE TO BE INSTALLED DURING
  RES BUILDING;
  ST

  ST
  K
  ST
  ST

  ST
  ST

  TAFUTUREDRIV OF CONSTRUCTION  OFFSITE IMPROVEMENTS TO
  ST  U PHASE  E RAN  CONNECT TO EXISTING SAN  PROPOSED MANHOLE  MH
  ST

  T 2, -THRU
  ST  ST
  ST
  MANHOLE 12 AT INV. 607.43.  WV
  ST

  ST
  380
  STOP

  ST
  ST

  STOP  REFER TO PLANS BY OTHERS.
  ST  ST
  ST
  SF  PROPOSED HYDRANT ASSEMBLY
  ST

  ST
OR TO PLUG  ST
  STOP

  Date:  07/20/26
  ST

AST INVERT;  ST
  APPROXIMATE LOCATION OF FUTURE  ST
  PROPOSED GATE VALVE  GV
  ST

DEMOLITION PLAN  PROPOSED 8" AWWA C-900
  STOP

  APPROXIMATE LOCATION OF FUTURE  SANITARY LATERAL FROM PROPOSED
  ST  ST  Drawn By:  C. Wood
  SANITARY LATERAL FROM PROPOSED  BUILDING; TO BE INSTALLED DURING  PVC COMBINED WATER  Scale:  As Noted
SAN MH 3  STOP  STOP  ST
  SERVICE (5' MIN. COVER)  NOTE: FOR PROPOSED VALVE BOXES, CLEANOUTS, ETC., INSTALL A
  ST

  BUILDING; TO BE INSTALLED DURING  FUTURE PHASE OF CONSTRUCTION
  ST

IM 614.36  STOP  ST  3,000 PSI CONCRETE COLLAR AROUND THE ITEM AT GRADE. THE DRAWING NO.
  FUTURE PHASE OF CONSTRUCTION  SAN MH 4  SAN MH 8
  ST

  COLLAR SHALL BE A MINIMUM OF 6" WIDER, ON ALL SIDES, THAN THE
  ST

NV 601.31  RIM 612.66
  UTILITY PLAN
  ST
  ST

  RIM 613.96  BOX, CLEANOUT, ETC. THE COLLAR SHALL BE A MINIMUM OF 6" THICK.

  C-402
  ST

NV 601.21  SE INV 601.94  FU  MAINTAIN 18" VERTICAL CLEARING AT
  ST

  RES TURE D
  STOP

  ST  SW INV 604.52
  ST
  ALL STORM/SANITARY CROSSINGS, TYP.
  N INV 601.84
  ST

  TAU RIV  NE INV 604.42
  STOP
  ST
  NOTE: BOUNDARY AND TOPOGRAPHIC INFORMATION PROVIDED BY OTHERS,
  ST
  ST

  ST
  RAN E-TH  SCALE: 1"=40'  CARMINA WOOD DESIGN ASSUMES NO RESPONSIBILITY FOR ITS ACCURACY.
  ST  133 LF  T, 2 RU
  ST

  ,300  PROPOSED PIPE CROSSING:
  ST

  ST
  10" SDR-35  Project No:  24-4113
  ST

  ST
  ST

  SF  8" SAN. INV= 604.55  40  0  40  80Ft.
  ST

  PVC @ 0.40%  ST  24" STORM INV=609.25  209 LF  40'
  PROPOSED PIPE CROSSING:
  PROPOSED PIPE CROSSING:  8" SDR-35  Page 1065 of 1174
  ST

  10" SAN. INV=601.18  ST
  ST
  ST