Text · page 1067 of 1174
Read the whole document on one page (all 1174 pages, each with its own heading)
DETECTABLE TAPE TRENCH WIDTH 1'-6" BELOW FINISHED GRADE (I.D. + 24") 6" TOPSOIL (MIN.) sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration. All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145 Greensboro 2 DETECTABLE TAPE EXCAVATED FROM TRENCH BACKFILL WITH MATERIAL 1'-6" BELOW FINISHED GRADE TRENCH WIDTH 12" (I.D.) 12" (I.D. + 24") 2 Utica 12" 1 . DIA O.D. Buffalo 12" (I.D.) 12" ) D. (I. TOP OF PIPE ZONE (6"MIN.) 1/3 I.D. (12"MAX.) 12" 1 . DIA O.D. D.) NOTES: (I. A. PIPE INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. (6"MIN.) 1/3 I.D. (12"MAX.) B. TRENCHING OPERATIONS SHALL INCLUDE ALL NECESSARY DEWATERING. C. TRENCH DETAILS ARE ONLY SHOWN FOR PURPOSES OF MATERIAL PLACEMENT AND MAXIMUM PAY LIMITS. D. AN OSHA APPROVED MOVABLE PROTECTIVE TRENCH SHIELD SHALL NOTES: BE USED IN ALL UNSHEETED TRENCH AREAS. A. PIPE INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. MATERIALS B. TRENCHING OPERATIONS SHALL INCLUDE ALL NECESSARY DEWATERING. West Seneca Exchange PIPE BEDDING MATERIAL (NYSDOT 1985 EDITION) C. TRENCH DETAILS ARE ONLY SHOWN FOR PURPOSES OF MATERIAL PLACEMENT AND MAXIMUM PAY LIMITS. 1 NO. 1 CRUSHED STONE OR CRUSHED GRAVEL WITH A GRADATION CONFORMING WITH NYSDOT SECTION 703-02. THE MATERIAL SHALL BE WELL GRADED WITH NO PARTICLES LARGER THAN ONE INCH AND HAVING A MAXIMUM GRADATION MEETING THE LIMITS D. AN OSHA APPROVED MOVABLE PROTECTIVE TRENCH SHIELD SHALL DESCRIBED IN THE SPECIFICATIONS. THE BEDDING SHALL BE COMPACTED IN 6" LIFTS WITH EQUIPMENT ACCEPTABLE TO THE PIPE BE USED IN ALL UNSHEETED TRENCH AREAS. Slade Ave, Ridge Rd & Orchard Park Rd MANUFACTURER. MATERIALS NO SLAG SHALL BE ALLOWED FOR MATERIAL 1 PIPE BEDDING MATERIAL (NYSDOT 1985 EDITION) 2 TYPE 2 CRUSHED STONE OR CRUSHED GRAVEL WITH A GRADATION CONFORMING WITH NYSDOT SECTION 304-2.02 TYPE 2. THE 1 NO. 1 CRUSHED STONE OR CRUSHED GRAVEL WITH A GRADATION CONFORMING WITH NYSDOT SECTION 703-02. THE MATERIAL MATERIAL SHALL BE WELL GRADED WITH NO PARTICLES LARGER THAN TWO INCHES AND HAVING A MAXIMUM GRADATION MEETING THESHALL BE WELL GRADED WITH NO PARTICLES LARGER THAN ONE INCH AND HAVING A MAXIMUM GRADATION MEETING THE LIMITS LIMITS DESCRIBED IN THE SPECIFICATIONS. THE BEDDING SHALL BE COMPACTED IN 6" LIFTS WITH EQUIPMENT ACCEPTABLE TO THE PIPEDESCRIBED IN THE SPECIFICATIONS. THE BEDDING SHALL BE COMPACTED IN 6" LIFTS WITH EQUIPMENT ACCEPTABLE TO THE PIPE MANUFACTURER. MANUFACTURER. NO SLAG SHALL BE ALLOWED FOR MATERIAL 1 West Seneca New York NO SLAG SHALL BE ALLOWED FOR MATERIAL 2 2 BACKFILL MATERIAL SHALL BE NATIVE SOIL CONTAINING NO UNSUITABLE MATERIAL COMPACTED IN 6" LIFTS. © CARMINA WOOD DESIGN SEWER/WATERLINE TRENCH SECTION IN PAVED AREAS SEWER/WATERLINE TRENCH SECTION NOT TO SCALE IN UNPAVED AREAS 8"METER & RPZ INSULATED ENCLOSURE NOT TO SCALE 'L' 'L' UNDISTURBED OR COMPACTED EARTH FINAL GRADE VALVE BOX COVER SHALL BE LABELED Date 'WATER' 2'-6" MIN. UNDISTURBED OR COMPACTED EARTH COLOR ELBOW FITTING, PUBLIC: YELLOW TEE FITTING, TYP. PRIVATE: RED TYP. PLAN PLAN THREE PIECE CAST IRON VALVE CONCRETE THRUST BOX WITH COVER BLOCK, TYP. CONCRETE THRUST BLOCK, TYP. FINISH GRADE BREAKAWAY NOTE SEE FLANGE, CLOSE No. Description WATER MAIN WATER MAIN TO FINISH TYP. TYP. GRADE 'H' 'H' REVISIONS: THREE PIECE CAST IRON VALVE BOX 4'-6" MIN. COVER ELEVATION ELEVATION DEPTH VARIES EXTENSION PIECES TO BE FURNISHED IF REQUIRED 6" GATE VALVE, HYDRANT SHUT-OFF 5-1/4" VALVE DIMENSION SCHEDULE OPENING PIPE 90° ELBOW 45° ELBOW 22.5° ELBOW 11.25° ELBOW VALVE SIZE 'H' 'L' 'H' 'L' 'H' 'L' 'H' 'L' 4" 1.5' 2.0' 1.0' 2.0' 1.0' 1.0' 1.0' 1.0' WATER MAIN 6" 2.0' 2.5' 1.5' 2.0' 1.0' 1.5' 1.0' 1.5' 8" 2.5' 3.5' 2.0' 2.5' 1.5' 1.5' 1.0' 2.0' 10" 3.0' 4.5' 2.5' 3.0' 1.5' 3.0' 1.0' 2.5' Sealed 07/20/2026 #4 STEEL REBAR ANCHOR ROD, 12" 3.5' 5.0' 3.0' 3.5' 2.5' 2.5' 1.5' 2.5' TYP. BEND AS REQ'D. CONCRETE ANCHOR BLOCK 2'-0" CONCRETE WIDE BLOCKING, TYP. DIMENSION SCHEDULE 1'-0" WATER MAIN FOR CONNECTION PIPE TEE OR TAP THRUST BLOCK SCHEDULE RESTRAIN JOINTS USING SIZE SLEEVE RETAINER GLANDS (TYP.) ---- 'H' 'L' 4" 1.5' 1.0' DIMENSION TO BE DETERMINED 6" 1.5' 2.5' IN THE FIELD 1'-0" MIN. NOTE: 8" 1.5' 3.5' CENTERLINE OF THE LOWEST NOZZLE TO FINISH GRADE SHALL MIN. OF 8 CU. FT. CRUSHED 10" 2.5' 3.5' STONE FOR HYDRANT DRAINAGE BE A MIN. OF 15" & MAX. 12" 3.5' 3.5' OF 18" TYPICAL GATE VALVE DETAIL NOT TO SCALE TYPICAL FIRE HYDRANT ASSEMBLY DETAIL DRAWING NAME: NOT TO SCALE Utility Details Date: 07/20/26 Drawn By: C. Wood Scale: As Noted DRAWING NO. C-404 Project No: 24-4113 Page 1067 of 1174