FRAME AND GRATE SHALL BE NEENAH  EXTERIOR CLEANOUT @ GRADE  CAP
  FRAME AND GRATE SHALL BE NEENAH R-1792-FG OR R-1792-FL W/"STORM" CAST IN  R-1792-FG OR R-1792-FL W/"STORM" CAST IN  J.R. SMITH #4251-U W/ VANDAL-
  COVER IF SOLID COVER IS SPECIFIED, HEAVY DUTY BICYCLE PROOF FRAME AND  COVER IF SOLID COVER IS SPECIFIED, HEAVY  PROOF SCREWS OR APPROVED EQUAL
  GRATE TO BE USED IN PARKING LOT AREAS UNLESS OTHERWISE SPECIFIED  DUTY BICYCLE PROOF FRAME AND GRATE TO
sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor
to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration.

  BE USED IN PARKING LOT AREAS UNLESS
All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145

  24" DIA.  TOP COURSE

  Greensboro
  OTHERWISE SPECIFIED  EXPANSION JOINT
  8"  STAND.  24" DIA.  BINDER

  2"
  STANDARD  WITH FIBERBOARD

  12" MIN.
  GRADE
  STONE BASE  4000 PSI CONCRETE ENCASE
  RISER RINGS W/GASKET  TO FULL DEPTH OF FRAME
  AS REQUIRED  RISER RINGS W/GASKET
  AS REQUIRED

  6" FOR IN-LINE CLEAN-OUT

  Utica
  TOP SLAB IS

  8"

  SEE PLANS
  SELECT FILL  8" FOR END OF LINE LAMPHOLE

  TYP.

  VARIES
  STEEL REINFORCED TO MEET

  12"
  OR EXCEED HS-20 LOADING.
  ECCENTRIC CONE

  (IF SPECIFIED)

  48" DIA. MIN.
  SECTION

  OR AS REQ'D

  Buffalo
  DET. A
  NOTE: ECCENTRIC CONE SECTION SHALL BE USED UNLESS  ALTERNATE TOP SLAB  FLOW
  DEPTH WARRANTS TOP SLAB PER MANUFACTURER

  SEE PLANS FOR
  SEWER SIZES
  FRAME OD + 2'

  GASKETED  STEEL REINFORCED COPOLYMER
  JOINT (TYP.)  POLYPROPYLENE PLASTIC STEP
  RISER SECTION

  LAMPHOLE/CLEANOUT IN PAVEMENT/SIDEWALK
  (IF REQ'D)

  NOT TO SCALE
  48" DIA. MIN.  5" MIN. OR
  OR AS REQ'D  AS REQ'D
  DETAIL A

  West Seneca Exchange
  NOTE: MANHOLE TO BE COATED ON OUTSIDE WITH  EXTERIOR CLEANOUT @ GRADE
  BITUMASTIC SEALER  J.R. SMITH #4251-U W/ VANDAL-
  PROOF SCREWS OR APPROVED EQUAL
  PVC CAP END  NOTE: COVER TO BE

  Slade Ave, Ridge Rd & Orchard Park Rd
  GENERAL NOTES:  INSCRIBED "SANITARY"
  2"x4" MARKER TO BE CUT 1'-0" BELOW
  1. REINFORCED STEEL TO CONFORM TO LATEST A.S.T.M. A185  GRADE AFTER FINAL FIELD WALK (END
  SPEC. 0.12 SQ. IN./LINEAL FT. AND 0.12 SQ. IN. (BOTH WAYS)  OF LINE CLEANOUTS ONLY)
  PIPE, SEE PLAN  IN BASE SLAB.
  FOR SIZE & INVERT

  2"
  2.  CONCRETE COMPRESSIVE STRENGTH - 4000 PSI MINIMUM.
  BASE SECTION

  FRAME OD+2'

  12"
  3.  MANHOLE DESIGN SPECIFICATIONS TO CONFORM TO LATEST
  12" MIN.

  A.S.T.M. C478 SPEC. FOR PRE-CAST REINFORCED CON-CRETE
  MANHOLE SECTIONS.

  SEE PLANS
  4000 PSI CONCRETE

  VARIES
  4.  SINGLE POUR MONOLITHIC BASE SECTION.  ENCASEMENT

  West Seneca New York
  24" MIN.
  8" THK.

  SEE PLANS
  © CARMINA WOOD DESIGN

  VARIES
  6"x6"x6" WYE
  6" MIN.

  PER TRENCH DETAIL
  #1STONE BEDDING
  (VARIES W/SIZE OF PIPE)

  12"
  COMPACTED TYPE 2 R.O.C. STONE BASE,
  NYSDOT ITEM 304.02

  TYPICAL SANITARY MANHOLE DETAIL
  NOT TO SCALE
  WATER TIGHT
  PVC END CAP  6" Ø PVC OR A SPECIFIED ON PLANS

  Date
  (END OF LINE CLEANOUTS ONLY)

  LAMPHOLE/CLEANOUT IN LAWN/FIELD AREAS
  NOT TO SCALE

  No. Description
  REVISIONS:

  Sealed 07/20/2026
  DRAWING NAME:

  Sanitary Sewer
  Details

  Date:  07/20/26
  Drawn By:  C. Wood
  Scale:  As Noted
  DRAWING NO.

  C-405
  Project No:  24-4113

  Page 1068 of 1174