Land Surveying
  Environmental
  SITE UTILITIES LEGEND

  Architecture
  Engineering
  PROPERTY LINE
  LIMIT OF DISTURBANCE AND SITEWORK
  CONTRACT LIMIT LINE
  SAWCUT LINE
  E  E  ELECTRIC LINE
  G  G  GAS LINE
  W  W  WATER LINE
  S  S  SANITARY SEWER LINE
  T  T  TELECOMMUNICATIONS LINE
  ETC  ELECTRIC AND TELECOMMUNICATIONS LINE  355 Research Parkway
  Meriden, CT 06450
  OH  OH  OVERHEAD ELECTRIC LINE  (203) 630-1406

  STORM LINE

  RESTAURANT 2,380 SF
  FUTURE DRIVE-THRU

  615
  7/17/2026

  615

  COSTCO WHOLESALE
  WEST SENECA, NEW YORK
  SLADE AVENUE
  PROVIDE AND INSTALL RIGID
  METAL CONDUIT DOWN POLE TO
  SUBSURFACE CONNECTION FOR
  PRIMARY ELECTRICAL SERVICES
  PROVIDE AND INSTALL (2) 6" PVC SCH 80 CONDUITS
  ENCASED IN CONCRETE AND WITH PULL STRINGS
  FOR ELECTRICAL SERVICE TO WAREHOUSE

  CAUTION
  CAUTION
  PROVIDE AND INSTALL
  TELECOMMUNICATIONS TRAFFIC
  RATED HANDHOLE PER UTILITY
  PROVIDER SPECIFICATIONS (TYP.)
  SHEET 3.01  SHEET 3.02  RELOCATE UTILITY POLE AND OVERHEAD
  WIRES, COORDINATE WITH UTILITY
  PROVIDERS. PER SITE PHOTOS, OVERHEAD
  LINE APPEARS TO BE FIBER OPTIC CABLES.
  CAUTION

  CAUTION
  CAUTION

  CAUTION
  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION
  CAUTION

  CAUTION

  UE
  N  REMOVE AND DISPOSE OF EXISTING
  CAUTION

  E
  GAS LINE TO BE RELOCATED.

  V
  COORDINATE WITH THE GAS

  Xref (s): ; XY240182401 ; XC2401824-10 ; XB2401824-00 ; XC2401824-20 ; XC2401824-21 ; XC2401824-30 ; XO2401824-01 ; KM2401824-KeyMap
  CAUTION

  CAUTION

  COMPANY FOR RELOCATION.

  A
  DN

  DN

  E
  PROVIDE AND INSTALL (4) 2" PVC
  SCH 80 CONDUITS WITH PULL

  D

  Desc.
  STRINGS FOR TELECOMMUNICATIONS
  SHEET 3.03  SHEET 3.04

  A
  SERVICE TO FUEL FACILITY

  L

  CAUTION

  CAUTION
  S

  CAUTION

  CAUTION

  REVISIONS
  PROVIDE AND INSTALL RIGID METAL CONDUIT DOWN
  POLE TO SUBSURFACE CONNECTION FOR PRIMARY

  Date
  TELECOMMUNICATIONS SERVICES
  KEY MAP

  No.
  PROVIDE AND INSTALL FIRE HYDRANT ASSEMBLY,
  6" DIP HYDRANT LATERAL, GATE VALVE, THRUST  Designed  J.J.L.
  BLOCKS, AND BOLLARDS AS REQUIRED BY LOCAL  Drawn  J.J.L.
  UTILITY PROVIDER AND/OR FIRE MARSHALL (TYP.)
7/17/2026, JLYNN, G:\JOBS24\18\2401824\DWG\C2401824-30.DWG.C3.01 24X36 30SC.

  Reviewed  K.A.K.
  Scale  1"=30'
  Project No.  2401824
  Date  07/17/2026
  CAD File:
  SMH-4  C2401824-30
  TF=619.83
  INV IN=611.97 (SE)  Title
  PROVIDE AND INSTALL TELECOMMUNICATIONS  INV OUT=611.87 (NE)  214LF 8" PVC @ 0.50%
  TRAFFIC RATED HANDHOLE PER UTILITY
  PROVIDER SPECIFICATIONS (TYP.)
  SITE UTILITY PLAN
  PROVIDE AND INSTALL (4) 4" AND (4) 2" PVC SCH
  80 CONDUITS WITH PULL STRINGS FOR
  PROVIDE AND INSTALL (4) 4" PVC SCH 80  TELECOMMUNICATIONS SERVICE
  CONDUITS WITH PULL STRINGS FOR  WV
  TELECOMMUNICATIONS SERVICE TO WAREHOUSE  Sheet No.

  C3.01
  GRAPHIC SCALE

  ISSUED FOR PERMITTING  30  15  0  30

  NOT RELEASED FOR CONSTRUCTION  SCALE IN FEET

  C 2026 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES.