Land Surveying
  Environmental
  SITE UTILITIES LEGEND

  Architecture
  Engineering
  PROPERTY LINE
  LIMIT OF DISTURBANCE AND SITEWORK
  CONTRACT LIMIT LINE
  610
  SAWCUT LINE  605
  E  E  ELECTRIC LINE
  G  G  GAS LINE
  W  W  WATER LINE
  S  S  SANITARY SEWER LINE
  T  T  TELECOMMUNICATIONS LINE

  STOP
  ETC  ELECTRIC AND TELECOMMUNICATIONS LINE  605  355 Research Parkway
  Meriden, CT 06450
  OH  OH  OVERHEAD ELECTRIC LINE  (203) 630-1406

  STOP
  STORM LINE

  RESTAURANT 2,380 SF

  605

  605
  FUTURE DRIVE-THRU  NE I
  RETAIL  SE I NV 606
  NE I  SW NV 606 .08
  RIM NV 608  PVC  2,925 G.S.F.  PVC  RIM INV 60 .18
  SAN 612.95 .73  8" S @ 0.5  8" S @ 0.5  SAN 613.17 6.18 610
  615
  MH
  11  189 DR-35 0%  FUTURE  301 DR-35 0%  MH
  9
  LF  LF
  7/17/2026
  STOP
  615
  615
  615  615  615
  NE I
  SW NV 607
  615  RIM INV 60 .69 615
  615  615
  SAN 613.26 7.79  615
  MH
  10
  615
  615

  615

  COSTCO WHOLESALE
  WEST SENECA, NEW YORK
  SLADE AVENUE
  RESTAURANT 2,380 SF
  PVC  FUTURE DRIVE-THRU
  8" S @ 0.5
  398 DR-35 0%
  LF

  PROVIDE AND INSTALL ELECTRIC  REMOVE AND DISPOSE OF
  TRAFFIC RATED HANDHOLE PER UTILITY  EXISTING GAS LINE TO BE
  PROVIDER SPECIFICATIONS (TYP.)  RELOCATED. COORDINATE
  WITH THE GAS COMPANY
  PROVIDE AND INSTALL TRANSFORMER,  FOR RELOCATION.
  PROVIDE AND INSTALL ELECTRIC
  TRANSFORMER PAD, AND BOLLARDS.
  CAUTION

  CAUTION
  CAUTION

  SECONDARY CONDUITS FROM

  CAUTION
  COORDINATE WITH ELECTRIC UTILITY PROVIDER.  TRANSFORMER TO FUEL FACILITY, NUMBER,
  TYPE, AND SIZE PER ELECTRICAL PLANS.
  COORDINATE CONNECTION TO
  DEVELOPER'S SANITARY SEWER SYSTEM.
  SHEET 3.01  SHEET 3.02  PROPOSED INV IN= 607.43 (SW)

  0%
  0.5
  @
  VC
  CAUTION

  CAUTION
  CAUTION

  CAUTION

  PROVIDE AND INSTALL FIRE HYDRANT ASSEMBLY,  "P
  6" DIP HYDRANT LATERAL, GATE VALVE, THRUST  SMH-8  F8
  3L
  BLOCKS, AND BOLLARDS AS REQUIRED BY LOCAL  TF=616.65  11
  UTILITY PROVIDER AND/OR FIRE MARSHALL (TYP.)  INV IN=608.03 (SE)
  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION

  CAUTION

  CAUTION
  CAUTION

  CAUTION
  CAUTION

  INV IN=608.09 (S)
  INV OUT=607.99 (N)

  CAUTION

  CAUTION

  WV
  PROVIDE AND INSTALL (4) 2" PVC SCH 80

  Xref (s): ; XY240182401 ; XC2401824-10 ; XB2401824-00 ; XC2401824-20 ; XC2401824-21 ; XC2401824-30 ; XO2401824-01 ; KM2401824-KeyMap
  CONDUITS WITH PULL STRINGS FOR
  CAUTION

  TELECOMMUNICATIONS SERVICE TO FUEL FACILITY
  CAUTION

  DN

  DN

  Desc.
  SHEET 3.03  SHEET 3.04
  CAUTION

  CAUTION
  CAUTION

  CAUTION

  REVISIONS
  CAUTION
  %

  CAUTION
  0
  0.5
  C@

  Date
  CAUTION
  CAUTION
  V
  "P
  KEY MAP  302L
  F8

  No.
  PROVIDE AND INSTALL FIRE HYDRANT ASSEMBLY,

  356LF 8" PVC @ 1.83%
  6" DIP HYDRANT LATERAL, GATE VALVE, THRUST  Designed  J.J.L.
  BLOCKS, AND BOLLARDS AS REQUIRED BY LOCAL  Drawn  J.J.L.
  UTILITY PROVIDER AND/OR FIRE MARSHALL (TYP.)
7/17/2026, JLYNN, G:\JOBS24\18\2401824\DWG\C2401824-30.DWG.C3.02 24X36 30SC.

  SMH-6  PROVIDE AND INSTALL FIRE HYDRANT ASSEMBLY,  Reviewed  K.A.K.
  SMH-5
  TF=619.44  TF=619.02  6" DIP HYDRANT LATERAL, GATE VALVE, THRUST  NW  Scale  1"=30'
  INV IN=610.80 (SW)  INV IN=611.84 (SE)  BLOCKS, AND BOLLARDS AS REQUIRED BY LOCAL
  INV
  INV IN=609.70 (SW)  RIM 608.1  Project No.  2401824
  INV OUT=610.70 (NE)  UTILITY PROVIDER AND/OR FIRE MARSHALL (TYP.)
  INV OUT=609.60 (N)  Date  07/17/2026
  SAN 615.15 7
  MH  CAD File:
  12  C2401824-30

  Title
  214LF 8" PVC @ 0.50%
  SITE UTILITY PLAN
  200LF 8" PVC @ 0.50%
  PROVIDE AND INSTALL 10"X6"X10" DIP
  PROVIDE AND INSTALL 10"X6"X10" DIP  TEE FITTING WITH RESTRAINED JOINTS
  TEE FITTING WITH RESTRAINED JOINTS  AND/OR THRUST BLOCK (TYP.)
  AND/OR THRUST BLOCK (TYP.)
  WV  WV
  74LF 6" HPP @ 2.00%  Sheet No.

  C3.02
  GRAPHIC SCALE

  ISSUED FOR PERMITTING  30  15  0  30

  NOT RELEASED FOR CONSTRUCTION  SCALE IN FEET

  C 2026 BL COMPANIES, INC. THESE DRAWINGS SHALL NOT BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION WITHOUT THE SPECIFIC WRITTEN PERMISSION OF BL COMPANIES.

  Page 1119 of 1174