Text · page 532 of 1174

Read the whole document on one page (all 1174 pages, each with its own heading)

WEST SENECA - POST DEVELOPMENT
E_App E_Post-Development Model_REV 2 NY-West Seneca 24-hr S1 100-yr Rainfall=5.22"
Prepared by Labella Associates  Printed 7/26/2026
HydroCAD® 10.20-6a s/n 09581 © 2024 HydroCAD Software Solutions LLC  Page 65

  Summary for Subcatchment PS-1A:

Runoff  =  1.29 cfs @ 12.04 hrs, Volume=  0.073 af, Depth= 3.77"
  Routed to Pond BIO-1A : Filtration Bioretention

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-72.00 hrs, dt= 0.01 hrs
NY-West Seneca 24-hr S1 100-yr Rainfall=5.22"

  Area (sf)  CN  Description
  3,892  98  Paved parking, HSG D
  6,228  80  >75% Grass cover, Good, HSG D
  10,120  87  Weighted Average
  6,228  61.54% Pervious Area
  3,892  38.46% Impervious Area

  Tc Length  Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  6.0  Direct Entry, Direct

  Subcatchment PS-1A:
  Hydrograph

  Runoff
  1.29 cfs

  NY-West Seneca 24-hr S1 100-yr
  Rainfall=5.22"
  Runoff Area=10,120 sf
  1  Runoff Volume=0.073 af
  Runoff Depth=3.77"
  Tc=6.0 min
  Flow (cfs)

  CN=87

  0
  0  2 4  6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72
  Time (hours)

  Page 532 of 1174