Southtowns Record

PB Agenda Packet 8.13.2026

Government
Town of West Seneca
Board
Planning Board
Meeting
Aug 13, 2026, 6:00 p.m.
Posted by publisher
Jul 28, 2026
Kind
Agenda packet
Topics
Water, sewer and drainage, Roads and traffic, Housing, Zoning and land use, Parks and recreation, Budget and taxes, Public safety

Original document

Same meeting

Text · page 585 of 1174

Read the whole document on one page (all 1174 pages, each with its own heading)

Isolator Row Plus Step By Step Maintenance Procedures
Step 1
Inspect Isolator Row Plus for sediment.
  A) Inspection ports (if present)
  i. Remove lid from floor box frame
  ii. Remove cap from inspection riser
  iii.	Using a flashlight and stadia rod,measure depth of sediment and record results on maintenance log.
  iv.	If sediment is at or above 3 inch depth, proceed to Step 2. If not, proceed to Step 3.
  B) All Isolator Row Plus
  i.	Remove cover from manhole at upstream end of Isolator Row Plus
  ii. Using a flashlight, inspect down Isolator Row Plus through outlet pipe
  1.	Mirrors on poles or cameras may be used to avoid a confined space entry
  2.	Follow OSHA regulations for confined space entry if entering manhole
  iii.	If sediment is at or above the lower row of sidewall holes (approximately 3 inches), proceed to Step
  2.
  If not, proceed to Step 3.

Step 2
Clean out Isolator Row Plus using the JetVac process.
 A) A
   fixed floor cleaning nozzle with rear facing nozzle spread of 45 inches or more is preferable
 B) Apply multiple passes of JetVac until backflush water is clean
 C) Vacuum manhole sump as required

Step 3
Replace all caps, lids and covers, record observations and actions.

Step 4
Inspect & clean catch basins and manholes upstream of the StormTech system.

  1) B)  2  1) A)

  4

Sample Maintenance Log
  Stadia Rod Readings  Sedi-
  Fixed point  ment
  Date  Fixed point  Observations/Actions  Inspector
  to top of
  to chamber  Depth
  sediment
  bottom (1)  (1)–(2)
  (2)
 3/15/11  6.3 ft  none  New installation. Fixed  DJM
  point is CI frame at grade

 9/24/11  6.2  0.1 ft  Some grit felt  SM

 6/20/13  5.8  0.5 ft  Mucky feel, debris visible  NV
  in manhole and in Isolator
  Row Plus, maintenance due  adspipe.com
 7/7/13  6.3 ft  0  System jetted and  DJM  800-821-6710
  vacuumed

ADS “Terms and Conditions of Sale” are available on the ADS website, www.adspipe.com
The ADS logo, StormTech®, the Isolator ® Row Plus and the Green Stripe are registered trademarks of Advanced Drainage Systems, Inc.
© 2025 Advanced Drainage Systems, Inc. #11081 5/25 CS

  Page 585 of 1174