24-4113 WEST SENECA EXCHANGE EXISTING  Type II 24-hr 1-Year Rainfall=1.87"
Prepared by Carmina Wood Design  Printed 7/13/2026
HydroCAD® 10.20-7a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 7

  Time span=0.00-60.00 hrs, dt=0.01 hrs, 6001 points
  Runoff by SCS TR-20 method, UH=SCS, Weighted-CN
  Reach routing by Dyn-Stor-Ind method - Pond routing by Dyn-Stor-Ind method

Subcatchment 1S: Existing - West  Runoff Area=5.700 ac 21.93% Impervious Runoff Depth=0.65"
  Flow Length=160' Slope=0.0280 '/' Tc=20.6 min CN=84 Runoff=3.92 cfs 0.310 af

Subcatchment 2S: Existing - Central  Runoff Area=22.800 ac 87.72% Impervious Runoff Depth=1.45"
  Flow Length=2,297' Tc=12.7 min CN=96 Runoff=44.18 cfs 2.753 af

Subcatchment 3S: Existing - East  Runoff Area=27.100 ac 97.79% Impervious Runoff Depth=1.65"
  Flow Length=2,297' Tc=12.7 min CN=98 Runoff=56.79 cfs 3.716 af

Link 4L: TOTAL EXISTING  Inflow=103.89 cfs 6.779 af
  Primary=103.89 cfs 6.779 af

  Total Runoff Area = 55.600 ac Runoff Volume = 6.779 af Average Runoff Depth = 1.46"
  14.12% Pervious = 7.850 ac 85.88% Impervious = 47.750 ac