24-4113 WEST SENECA EXCAHNGENY-WestSeneca_NOAA14 24-hr S1 25-yr Rainfall=4.10"
Prepared by Carmina Wood Design  Printed 7/13/2026
HydroCAD® 10.20-7a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 37

  Summary for Subcatchment 1S: Proposed - West

[47] Hint: Peak is 1145% of capacity of segment #2

Runoff  =  107.55 cfs @ 12.02 hrs, Volume=  5.310 af, Depth= 3.32"
  Routed to Pond 18P : POND

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-150.00 hrs, dt= 0.01 hrs
NY-WestSeneca_NOAA14 24-hr S1 25-yr Rainfall=4.10"

  Area (ac)  CN  Description
  5.060  80  >75% Grass cover, Good, HSG D
  4.110  98  Roofs, HSG D
  10.040  98  Paved parking, HSG D
  19.210  93  Weighted Average
  5.060  26.34% Pervious Area
  14.150  73.66% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  1.8  100 0.0100  0.92  Sheet Flow, pavement
  Smooth surfaces n= 0.011 P2= 2.50"
  3.0  950 0.0080  5.32 9.40 Pipe Channel, 18" PIPE
  18.0" Round Area= 1.8 sf Perim= 4.7' r= 0.38'
  n= 0.013 Corrugated PE, smooth interior
  4.8 1,050 Total

  Subcatchment 1S: Proposed - West
  Hydrograph

  120
  Runoff
  115  107.55 cfs
  110
  105
  NY-WestSeneca_NOAA14 24-hr S1 25-yr
  100  Rainfall=4.10"
  95  Runoff Area=19.210 ac
  90  Runoff Volume=5.310 af
  85
  80
  Runoff Depth=3.32"
  75  Flow Length=1,050'
  70  Tc=4.8 min
  Flow (cfs)

  65
  CN=93
  60
  55
  50
  45
  40
  35
  30
  25
  20
  15
  10
  5
  0
  0  10  20  30  40  50  60  70  80  90  100  110  120  130  140  150
  Time (hours)