24-4113 WEST SENECA EXCAHNGENY-WestSeneca_NOAA14 24-hr S1 25-yr Rainfall=4.10"
Prepared by Carmina Wood Design  Printed 7/13/2026
HydroCAD® 10.20-7a s/n 05019 © 2025 HydroCAD Software Solutions LLC  Page 45

  Summary for Pond 16P: OUTLET PIPE

Inflow Area =  59.695 ac, 80.80% Impervious, Inflow Depth = 3.49" for 25-yr event
Inflow  =  109.83 cfs @ 12.05 hrs, Volume=  17.346 af
Outflow  =  109.83 cfs @ 12.05 hrs, Volume=  17.346 af, Atten= 0%, Lag= 0.0 min
Primary  =  109.83 cfs @ 12.05 hrs, Volume=  17.346 af
  Routed to Link 13L : TOTAL

Routing by Dyn-Stor-Ind method, Time Span= 0.00-150.00 hrs, dt= 0.01 hrs
Peak Elev= 607.58' @ 12.05 hrs
Flood Elev= 612.00'

Device  Routing  Invert  Outlet Devices
  #1  Primary  603.56'  58.0" W x 94.0" H Box Culvert
  L= 641.0' RCP, square edge headwall, Ke= 0.500
  Inlet / Outlet Invert= 603.56' / 601.35' S= 0.0034 '/' Cc= 0.900
  n= 0.013 Concrete pipe, bends & connections, Flow Area= 37.86 sf

Primary OutFlow Max=109.70 cfs @ 12.05 hrs HW=607.58' TW=0.00' (Dynamic Tailwater)
  1=Culvert (Barrel Controls 109.70 cfs @ 7.54 fps)

  Pond 16P: OUTLET PIPE
  Hydrograph

  Inflow
  109.83 cfs  Primary
  120  109.83 cfs
  115
  110  Inflow Area=59.695 ac
  105
  100  Peak Elev=607.58'
  95
  90
  85
  58.0" x 94.0"
  80
  75  Box Culvert
  Flow (cfs)

  70
  65  n=0.013
  60
  55
  50
  L=641.0'
  45
  40  S=0.0034 '/'
  35
  30
  25
  20
  15
  10
  5
  0
  0  10  20  30  40  50  60  70  80  90  100  110  120  130  140  150