NEW YORK STATE BUILDING 2025  1.  ALL ON SITE WORK WILL BE IN ACCORDANCE WITH LOCAL AND 2020 IRC
  PER NYS 1.  2.  STOOPS, STAIRS, HANDRAILS, GUTTERS, DOWNSPOUTS AND SPLASH BLOCKS WILL BE
  SUPPLIED AND INSTALLED BY OTHERS.
1.  RESIDENTIAL CODE R311 MEANS OF EGRESS, ALL STAIRWAYS, RAMPS, HALLWAYS AND DOORS  8.  ALL DRAIN AND WASTE VENTS THRU THE ROOF SHALL BE 3" AND TERMINATE A MINIMUM
  SHALL COMPLY TO THIS SECTION  18" ABOVE THE POINT IT PASSES THROUGH THE ROOF
2. RESCHECK ENERGY CODE CALCULATIONS FORMAT FOR EACH SPECIFIC BUILDING, WILL BE  9.  ALL EXTERIOR ELECTRICAL OUTLETS WILL BE G.F.I. CIRCUIT
  PROVIDED TO LOCAL BUILDING OFFICIALS.  10.  ALL SIDING WILL BE INSTALLED IN ACCORDANCE WITH 2015 INTERNATIONAL RESIDENTIAL
3. MINIMUM ROOM AREAS, HABITABLE SPACES SHALL NOT BE LESS THAN 70.0 S.F. MINIMUM  CODE
  CLEAR FLOOR AREA AND SHALL NOT HAVE A HORIZONTAL DIMENSION OF NOT LESS THAN 7'-0".  11.  ANY CHIMNEY STRUCTURES SHALL BE INSTALLED ON SITE BY OTHERS IN ACCORDANCE
4. LIGHT, VENTILATION AND HEATING, ALL HABITBALE ROOMS SHALL HAVE A GLAZING AREA OF  WITH ALL LOCAL AND STATE BUILDING CODES
  NOT LESS THAN 8% OF THE FLOOR AREA AND THE MINIMUM OPEN AREA TO 5. THE OUTDOORS  12.  ALL ELEVATIONS ARE SHOWN WITH STANDARD ROOF PITCH. SEE CROSS-SECTIONS FOR
  SHALL BE 4% OF THE FLOOR AREA. BATHROOMS OR WATER CLOSET COMPARTMENTS SHALL  OPTIONAL ROOF DETAILS
  HAVE A GLAZING AREA OF NOT LESS THAN 3.0 S.F., ONE HALF OF WHICH MUST BE OPENABLE  13.  GLAZING. TESTING AND LABELING. IF APPLICABLE, UNIT SKYLIGHTS SHALL BE TESTED
  WITH THE EXCEPTION THAT IS THE ROOM IS MECHANICALLY VENTED AND IS ARTIFICALLY  AND APPROVED IN COMPLIANCE WITH AAMA/WDMA 101/I.S.2/NAFS PER 2020
  LIGHTED.  14.  ALL ROOF COVERING MATERIALS AND ROOF COVERING INSTALLATION SHALL BE IN
6. GLAZING, SAFETY GLAZING SHALL BE IN FIXED OR OPERABLE DOORS, SLIDING DOORS, AROUND  ACCORDANCE WITH 2020
  BATHTUBS AND SHOWERS, GLAZING WITH THE BOTTOM EDGE LESS THAN 18" ABOVE THE
  FLOOR, EXPOSED GLAZING IS OVER 9.0 S.F.. ALSO, WINDOW FALL PROTECTION IS REQUIRED
  WHERE A FALL HAZARD EXISTS PER IRC R312.2
7. ALL MATERIALS, CONSTRUCTION, ASSEMBLIES, AND EQUIPTMENT SHALL CONFORM TO THE
  REGULATIONS OF THE STATE UNIFORM FIRE PREVENTION AND BUILDING CODE AND
  GENERALLY ACCEPTED STANDARDS.  1.  FIRE RATED ASSEMBLIES BOTH WALL AND FLOOR/CEILING SHALL BE SUPPORTED BY
8. DWELLING UNIT SEPARATION AND SLEEPING UNIT SEPARATION SHALL BE WALL AND/OR FLOOR  CONSTRUCTION OF THE SAME OR GREATER FIRE RATING DOWN TO THE FOUNDATION.
  ASSEMBLIES HAVING NOT LESS THAN A 1-HOUR FIRE RESISTANCE RATING IN ACCORDANCE  2. STRUCTURAL SHEATHING AND PLASTIC INSULATION SHALL BE ATTACHED TO THE
  WITH ASTM E119. OPENINGS IN FIRE RATED ASSEMBLIES SHALL BE 3 4 HOUR RATED DOOR  OUTSIDE OF FIRE RATED WALLS EXCEPT WHERE SHOWN ON FIRE RATED DETAILS.
  ASSEMBLIES WITH SELF-CLOSURES  3. DOORS AND FRAMES THRU FIRE RATED WALLS SHALL BE 3 4 HOUR RATED AND DOORS TO
9. DISCRETE MODELS (PLANS HAVING THE SAME SPECIFIC ROOM ARRANGEMENT &/OR  BE SELF-CLOSING.
  ARCHITECTURAL STYLE) SHALL BE PREPARED FROM THESE DRAWINGS WITHOUT  4. NO PLASTIC PIPE TO PENETRATE FIRE RATED ASSEMBLIES INCLUDING FLOOR/CEILING.
  MODIFICATION, ADDITION OR DELETION IN ANY MANNER.  RELOCATE OR USE METAL PIPE FROM A MINIMUM OF ABOVE FIRE RATED ASSEMBLY AND
10. ROOF COVERING SHALL BE OF CLASS A, B, OR C PER NYS RR902, ROOF CLASSIFICATION  DOWN.
  CONCEALED VERTICAL SPACE SHALL BE FIRE STOPPED AT EACH LEVEL & NOT BE CONTINUOUS  5. ON FIRE RATED ASSEMBLIES, FASTENINGS SHALL NOT PENETRATE GYPSUM BOARD
  WITH CONCEALED HORIZONTAL SPACES. FLOOR PLENUMS UNDER RATED WALLS SHALL BE  EXCEPT AT STUD. SIDING SHALL BE FURRING WHERE NECESSARY.
  FIRE STOPPED.  6. INSULATION SHALL BE INSTALLED UNDER FLOOR AND BE SUPPORTED BY FLOOR JOISTS
11. 2017 UCS FOR NEW STATE CODES, SMOKE ALARMS, CARBON MONOXIDE ALARMS, SMOKE  AND NOT CEILING.
  ALARMS SHALL BE INSTALLED IN EACH SLEEPING ROOM, OUTSIDE EACH SLEEPING AREA, EACH  7. THE SAME FIRE ASSEMBLY SHALL RUN FROM FOUNDATION TO ROOF.
  STORY OF THE DWELLING AND SHALL BE HARDWIRED AND INTERCONNECTED, CARBON  8. STRUCTURAL LUMBER MAY BE SUBSTITUTED BY A SPECIES AND/OR GRADE OF LUMBER
  MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE  WITH EQUAL OR GREATER VALUES.
  VICINITY OF THE BEDROOMS AND EACH STORY OF THE DWELLING. STRUCTURES 3-STORIES OR  9. ALL STUDS SHALL BE GRADE LUMBER.
  MORE IN HEIGHT REQUIRED SPRINKLER SYSTEMS  10. ROOF SHINGLES ARE FACTORY INSTALLED (NAILED) EXCEPT AT RIDGE. SHINGLES ARE
12. CENTER MATING WALL / FIRE / TENANT SEPARATION WALL EXTENDS TO UNDERSIDE OF ROOF  SUPPLIED FOR IN SITE INSTALLATION AT RIDGE.
  SHEATHING TO ENSURE THE CONTINUITY OF THE FIRE SEPARATION  11. ALL SEAL DOWN TAB SHINGLES ARE U.L. CLASS "C" WITH SHINGLE UNDERLAYMENT OF 15#
13. ALL STRUCTURAL FRAMING INCLUDING FLOOR JOIST SPANS, CEILING FRAMING SPANS, ROOF  FELT OR BETTER.
  RAFTER SPANS, GIRDER SPANS AND HEADER SPANS SHALL COMPLY WITH NYS RESIDENTIAL  12. FLOOR INSULATION SUPPLIED AND INSTALLED BY BUILDER AS REQUIRED.
  13. ALL WINDOWS AND EXTERIOR DOORS THAT ARE FACTORY INSTALLED, ARE CAULKED AND
  ROOF PLAN NOTES
  CODES CHAPTER 5, CHAPTER 6, CHAPTER 8 AND CHAPTER 9
14. DRAFTSTOPS, FIRESTOPS AND FIRE BLOCKING SHALL BE INSTALLER PER NYSBC 2020  FLASHED PER 2016 NYS CODE 703 EXTERIOR COVERING IN THE FACTORY. FIELD
15. EACH DWELLING SHALL HAVE A PRIMARY LOCATION MAIN ENTRANCE DOOR. THIS DOOR SHALL  INSTALLED WINDOWS AND DOORS ARE TO BE CAULKED ON SITE BY THE BUILDER.
  BE BOTH SWING TYPE AND 36" MININUM WIDE OF NOT VENTED MECHANICALLY TO THE  14. ICE AND WATER SHIELD INSTALLED IN THE FACTORY AT ALL EAVES A MINIMUM 24"
  BEYOND OR INSIDE THE EXTERIOR WALL LINE. ICE AND WATER SHIELD AT VALLEYS SHALL  ALL DOWNSPOUTS SHALL BE TERMINATED IN AN APPROPRIATE
  EXTERIOR, BATHROOMS AND TOILET ROOMS SHALL HAVE A MINIMUM OPENABLE AREA OF 1 21
  BE INSTALLED ON SITE BY THE BUILDER. UNDERLAYMENT APPLICATION SHALL CONFORM
  SQ.FT., 3 SQ.FT. FOR KITCHENS (60 SQ.FT. OR MORE) SHALL HAVE 4% OF FLOOR AREA OPENING
  TO 2015 INTERNATIONAL RESIDENTIAL CODES  MANNER INTO AN ADJACENT GUTTER AND DOWN TO GRADE INTO
  FOR MINIMUM VENTILATION.
  15. ALL PENETRATIONS IN AIR VAPOR BARRIER SHALL BE MADE AIR TIGHT. THE VAPOR  A STORM WATER RECEIVER.
16. GARAGES AND ATTACHED GARAGES SHALL BE SEPARATED BY A 34 HOUR FIRE RATED WALL  BARRIER (BUILDING ENVELOPE) SHALL BE MADE DURABLY SEALED PER NYS CODE
  MINIMUM. EACH OPENING IN WALL SHALL HAVE A 34 HOUR RATING AND SELF-CLOSING DOOR.  CHAPTER 11 ENERGY EFFICIENCY, R1102.4 AIR LEAKAGE (MANDATORY)  MAINTAIN A MINIMUM SLOPE FOR ALL GUTTERS TO DOWNSPOUT
17. ALL GARAGE BEARING WALLS AND GIRDERS REQUIRE A 34 HOUR FIRE RATING PER UL #'S 307,  16. ALL ON SITE CONSTRUCTION SHALL MAINTAIN A CONTINUOUS AIR VAPOR BARRIER.
  413 AND 531  17. JOINTS BETWEEN MODULES AND FOUNDATION SHALL BE MADE AIR TIGHT ON SITE BY
  LOCATIONS.
18. INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH NYS CODE R702  BUILDER.
19. INTERIOR WALL AND CEILING FINISHE MATERIALS IN ANY LOCATION SHALL BE CLASS C  18. ALL INSULATION SHALL BE IN ACCORDANCE WITH 2020 UCS AND MATCH CURRENT  CHECK PROJECTIONS, EAVES & DECK FOR ADEQUACY OF
20. COMPONENT AND CLADDING LOADS, ROOF SHINGLE NAILING, PROTECTION OF OPENINGS ARE  RESCHECK VERSION  ANCHORAGE, FOREIGN MATERIAL, MOISTURE OR UNEVENNESS
  AS REGULATED BY APPROPRIATE PRESCRIPTIVE SECTIONS OF THE 2017 UCS UNIFORM CODE  19. EXTENDED AIR BAFFLES SHALL MATCH AREA OF ADJACENT EAVE VENT PER NYSBC 2020
  SUPPLEMENT  20. ALL DUCT SEALING AND TESTING SHALL BE IN ACCORDANCE WITH NYSBC 2020
  THAT WOULD PREVENT EXECUTION OF WORK.
  21. ROOF VENTILATION SHALL BE IN ACCORDANCE WITH NYSBC 2020
  ALL SURFACES THAT ARE TO RECEIVE ROOFING OR FLASHING.
  SHALL BE THOROUGHLY DRY. SHOULD SURFACE MOISTURE
  OCCUR, CONTRACTOR SHALL PROVIDE NECESSARY EQUIPMENT
  TO DRY SURFACE PRIOR TO APPLICATION.
  ■ Design Build Alarm System
  ■ Design Build Audio/ sound/ Video system  ONLY AS MUCH OF THE NEW ROOFING AS CAN BE MADE
  ■ Existing Sprinkler System  WEATHER TIGHT EACH DAY, INCLUDING ALL FLASHING, SHALL BE
  INSTALLED.

  ALL WORK SHALL BE SCHEDULED & EXECUTED WITHOUT
  EXPOSING THE INTERIOR OF THE BUILDING AREAS TO THE
  EFFECTS OF INCLIMATE WEATHER. THE EXISTING BUILDING & ITS
  CONTENTS SHALL BE PROTECTED AGAINST ALL RISKS.

  ALL NEW OR TEMPORARY CONSTRUCTION INCLUDING
  EQUIPMENT & ACCESSORIES SHALL BE SECURED IN SUCH A
  MANNER AT ALL TIMES AS TO PRECLUDE BLOW-OFF & OR WIND
  DAMAGE.

  ROOFING, FLASHING, INSULATION & ICE SHIELD SHALL BE
  INSTALLED TO ENTIRE ROOF IN STRICT ACCORDANCE WITH
  MANUFACTURERS
  SPECIFICATIONS & SHALL BE APPLIED ONLY BY A CONTRACTOR
  AUTHORIZED BY ROOFING MANUFACTURER.

  SCHENNE & ASSOCIATES  BRIAN ARCHER  HOME RENOVATION
  CONSULTING ENGINEERS
3  20260709  CHG SM TO LAYOUT
  967 Luther Road  417 PROSPECT AVE,  417 PROSPECT AVE,  NOTES
2  20260625  CHG SM TO SCO ON 2FL
  East Aurora, NY 14052
1  20260618 + BASEMENT WDOW
  (716) 655-4991; [email protected]
  EAST AURORA, NY 14052  EAST AURORA, NY 14052
  SCALE:  AS NOTED  DATE:  20260326  DWG.  A-0