Text · page 138 of 169
Read the whole document on one page (all 169 pages, each with its own heading)
MICROWAVE W/ INTEGRAL VENTILATION INSTALLED ABOVE COOKING RANGE PER MANUFACTURERS INSTRUCTIONS AND VENTED AS NECESSARY IAW RCNYS TABLE M1504.2 ENCLOSE EXISTING OPENING DEMO EXISTING WALL AND RE-BUILD W/ 2X6 FRAMING EXISTING 2X8 FLOOR FRAMING W/ 5/8" SUBFLOOR STAIRCASES MOVED ENSURE STEPS AND HANDRAILS MEETS RCNYS 2025 REQ'S BUILT OUT PLUMBING PARTITION - 6" PARTITION IN FRONT OF STAIRCASE HEADER, CAN BE VARIABLE EG FOR PLUMBING SPACING MOVE STAIRCASE; HEAD HEIGHT MUST BE 6'8" (MIN) EG RISER HEIGHT: 7-3/4" (MAX), TREAD DEPTH: 10" (MIN) EGRESS WINDOW MIN U-FACTOR 36" CLEAR MIN WIDTH W/ HANDRAILS ON BOTH SIDES 0.27 AND SHGC OF 0.40 EG EG PT 6X6 POSTS W/ 22" D X 48" DEPTH SONOTUBE FOOTER, CONNECTED USING CBSTQ66 COLUMN BASE 2ND FLOOR PLAN 2 1ST FLOOR PLAN 1 SCALE: 1/4"=1'-0" A-1 SCALE: 1/4"=1'-0" A-1 SCHENNE & ASSOCIATES BRIAN ARCHER HOME RENOVATION CONSULTING ENGINEERS 3 20260709 CHG SM TO LAYOUT 967 Luther Road 417 PROSPECT AVE, 417 PROSPECT AVE, FLOOR PLANS 2 20260625 CHG SM TO SCO ON 2FL East Aurora, NY 14052 1 20260618 + BASEMENT WDOW (716) 655-4991; [email protected] EAST AURORA, NY 14052 EAST AURORA, NY 14052 SCALE: AS NOTED DATE: 20260326 DWG. A-1