Text · page 139 of 169
Read the whole document on one page (all 169 pages, each with its own heading)
ROOF CONSTRUCTION · 30 YEAR ASPHALT ROOF SHINGLES · CONT'D ICE SHIELD OVER ENTIRE ROOF AREA · 5/8" OSB SHEETING, REFER TO APA INSTALLING GUIDELINES · EXISTING DAMAGE 2X6 RAFTERS · NEW 2X10 WD. RAFTERS @16" O.C. · OR REPAIR/ SISTERED EXISTING FLOOR JOISTS W/ NEW ATTIC <A FLOOR JOISTS 2X6 @12"O.C. IR · NEW R-49 INSULATION FL AIR BAFFLES BETWEEN EACH OW RAFTER LOCATION ATTIC FLR JTS. > METAL DRIP EDGE ALUMIN. GUTTER INSULATION IS R-20 EXTERIOR WALL CONSTRUCTION CAVITY + 10 CI · SIDING COLOR BY OWNER · TYVEX WEATHER BARRIER · 1/2" EXTERIOR OSB SHEATHING AS SPECIFIED · 2X6 WD. FRAMING @ 16" O.C. MIN. · 6 MIL. POLY VAPOR BARRIER · 1/2" G.W.B. AT INTERIOR WALLS · (3) 2x6 WD TOP PLATES WALL-ROOF SECTION DETAIL 2 SCALE: NTS A-2 ROOF PLAN 1 SCALE: 3/8"=1'-0" A-2 SCHENNE & ASSOCIATES CONSULTING ENGINEERS BRIAN ARCHER HOME RENOVATION 3 20260709 CHG SM TO LAYOUT 417 PROSPECT AVE, ROOF PLAN 2 20260625 CHG SM TO SCO ON 2FL 967 Luther Road 417 PROSPECT AVE, East Aurora, NY 14052 1 20260618 + BASEMENT WDOW (716) 655-4991; [email protected] EAST AURORA, NY 14052 EAST AURORA, NY 14052 SCALE: AS NOTED DATE: 20260326 DWG. A-2