WNY-2500056.00_HydroCAD  extreme_precip_tables_output (29) 24-hr S1 1-yr Rainfall=1.88"
Prepared by Greenman-Pedersen, Inc  Printed 12/18/2025
HydroCAD® 10.20-7a s/n 04560 © 2025 HydroCAD Software Solutions LLC  Page 10

  Summary for Subcatchment AQR: Area to Quaker Road

Runoff  =  0.24 cfs @ 12.06 hrs, Volume=  0.014 af, Depth> 1.28"
  Routed to Link PRE : Pre-Development

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
extreme_precip_tables_output (29) 24-hr S1 1-yr Rainfall=1.88"

  Area (ac)  CN  Description
  0.100  98  Paved parking, HSG D
  0.030  80  >75% Grass cover, Good, HSG D
  0.130  94  Weighted Average
  0.030  23.08% Pervious Area
  0.100  76.92% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  3.3  18 0.0408  0.09  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.20"
  0.7  37 0.0196  0.93  Sheet Flow,
  Smooth surfaces n= 0.011 P2= 2.20"
  4.0  24 0.0429  0.10  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.20"
  8.0  79 Total

  Subcatchment AQR: Area to Quaker Road