WNY-2500056.00_HydroCAD  extreme_precip_tables_output (29) 24-hr S1 1-yr Rainfall=1.88"
Prepared by Greenman-Pedersen, Inc  Printed 12/18/2025
HydroCAD® 10.20-7a s/n 04560 © 2025 HydroCAD Software Solutions LLC  Page 13

  Summary for Subcatchment ASP: Area to Southern Property

Runoff  =  0.06 cfs @ 12.35 hrs, Volume=  0.007 af, Depth> 0.49"
  Routed to Link PRE : Pre-Development

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
extreme_precip_tables_output (29) 24-hr S1 1-yr Rainfall=1.88"

  Area (ac)  CN  Description
  0.170  80  >75% Grass cover, Good, HSG D
  0.170  100.00% Pervious Area

  Tc  Length Slope Velocity Capacity Description
  (min)  (feet)  (ft/ft) (ft/sec) (cfs)
  25.4  135 0.0138  0.09  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.20"

  Subcatchment ASP: Area to Southern Property