DRAINAGE COMPUTATIONS
  TRIBUTARY  RUNOFF  TIME OF  REQUIRED  DESIGN  EXISTING
  SEWER LOCATION  PROFILE
  AREA  COEFFICIENT  CONCENTRATION  CAPACITY  n=  0.012  CAPACITY

  A  ΣA  IN CHANNEL  Tc  i  q  D  V  Qfull  LENGTH  s  Q  %
DRAINAGE AREAS  FROM  TO  C  CA  ΣCA  Drop  Invert  Rim  Cover
  (ac)  (ac)  (sec)  (min)  (min)  (in/hr)  (cfs)  (in)  (fps)  (cfs)  (ft)  (%)  (cfs)  REQ'D

  DA 4  RCVR 4  RCVR 5  0.08  0.08  0.80  0.06  0.06  9.77  0.16  5.00  5.28  0.34  8  2.25  0.83  22  0.40%  0.09 901.13  903.24  1.45
  DA 5  RCVR 5  Swale  0.05  0.13  0.80  0.04  0.10  35.19  0.59  5.16  5.22  0.54  8  2.53  0.83  89  0.40%  0.36 901.04  903.54  1.83
  DA 6  Swale  RCVR 1  0.16  0.29  0.60  0.10  0.20  12.11  0.20  15.00  3.36  0.67  8  2.64  0.83  32  0.40%  0.13 900.68
  DA 1  RCVR 1  RCVR 2  0.06  0.35  0.80  0.05  0.25  21.82  0.36  15.20  3.34  0.83  8  2.70  0.83  59  0.40%  0.24 900.56  903.51  2.29
  DA 3  RCVR 3  RCVR 2  0.15  0.15  0.80  0.12  0.12  14.92  0.25  5.00  5.28  0.63  8  2.61  0.83  39  0.40%  0.16 900.48  903.65  2.51
  DA 2  RCVR 2  Ex RCVR  0.01  0.51  0.80  0.01  0.38  16.88  0.28  15.57  3.30  1.24  8  4.27  1.31  72  1.00%  0.72 900.32  904.11  3.12

  LOCATION: 359 Quaker Road
  COMPUTED BY:  JJS  DATE:  12/18/25  SHEET  1
  CHECKED BY:  DATE:  OF  1