WNY-2500056.00_HydroCAD  extreme_precip_tables_output (29) 24-hr S1 100-yr Rainfall=5.25"
Prepared by Greenman-Pedersen, Inc  Printed 12/18/2025
HydroCAD® 10.20-7a s/n 04560 © 2025 HydroCAD Software Solutions LLC  Page 53

  Subcatchment AEP: Area to Eastern Property
  Hydrograph

  Runoff
  0.6  0.57 cfs
  extreme_precip_tables_output (29) 24-hr S1 100-yr
  0.55  Rainfall=5.25"
  Runoff Area=0.090 ac
  0.5  Runoff Volume=0.029 af
  Runoff Depth>3.91"
  0.45  Flow Length=27'
  Slope=0.0521 '/'
  0.4
  Tc=4.1 min
  CN=88
  Flow (cfs)

  0.35

  0.3

  0.25

  0.2

  0.15

  0.1

  0.05

  0
  0  1  2  3  4  5  6  7  8  9  10  11 12 13 14  15  16  17  18  19  20  21  22  23  24