WNY-2500056.00_HydroCAD  extreme_precip_tables_output (29) 24-hr S1 1-yr Rainfall=1.88"
Prepared by Greenman-Pedersen, Inc  Printed 12/18/2025
HydroCAD® 10.20-7a s/n 04560 © 2025 HydroCAD Software Solutions LLC  Page 12

  Summary for Subcatchment DA 1: Drainage Area 1

Runoff  =  0.17 cfs @ 11.98 hrs, Volume=  0.008 af, Depth> 1.66"
  Routed to Pond RCVR 1 : RCVR 1

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
extreme_precip_tables_output (29) 24-hr S1 1-yr Rainfall=1.88"

  Area (ac)  CN  Description
  0.060  98  Paved parking, HSG D
  0.060  100.00% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  1.6  80 0.0100  0.83  Sheet Flow,
  Smooth surfaces n= 0.011 P2= 2.20"

  Subcatchment DA 1: Drainage Area 1