Text · page 116 of 219
Read the whole document on one page (all 219 pages, each with its own heading)
PART 8 General Development Standards 93 OF 148 q. Other information: such additional i. Notwithstanding the provisions set forth information as may be reasonably in these subsections, such setbacks from requested by the Technical Support lot lines do not apply if the application Department, Code Enforcement Officer, is accompanied by a legally enforceable Planning Board, or City Council. agreement for a period of 25 years or the life of the permit, whichever is longer, that B. Special use permits issued for wind energy the adjacent landowner agrees to the conversion systems shall be subject to the elimination of the setback. following conditions: 2. Maximum overall height. The maximum 1. Setbacks. The applicant shall adhere to the overall height of any wind energy conversion following setbacks: system shall be 450 feet. The maximum a. No commercial wind energy systems shall height shall be measured from the ground be allowed in any residential district. elevation to the top of the tip of the blade in b. One thousand feet from any residential the vertical position. district boundary line. 3. Signage. No advertising sign shall be placed c. A minimum of 1.5 times the total WECS or painted on any commercial wind energy height from any building located outside facility. the applicant's property line. 4. Color and finish. Wind turbines shall d. A minimum of 1,500 feet from any be painted a nonobtrusive (e.g., light dwelling. environmental color such as white, gray, or beige) color that is nonreflective. The design e. (From property lines (excluding residential of commercial wind energy facility buildings zones and the BRA): and related structures shall, to the extent i. A minimum of 1.5 times the total reasonably possible, use materials, colors, WECS height from any property line, textures, screening and landscaping that will excluding adjoining lot lines of project blend the facility to the natural setting and participants. the existing environment. f. A minimum of 1.5 times the total WECS 5. Lighting. The applicant shall submit a height from any public road and highway. commercial wind energy facility lighting plan that describes all lighting that will be g. Where the lot line abuts a public right- required, including any lighting that may be of-way, the setbacks specified above shall required by the FAA. Such plan shall include be measured from the center line of such but is not limited to the planned number and right-of-way. location of lights, light color, whether any h. From aboveground transmission lines such lights will be flashing, and mitigation greater than 12 kilovolts: measures planned to control the light so i. A minimum of 1.5 times the total that it is does not spill over onto neighboring WECS height from any aboveground properties. transmission line greater than C. Compliance with regulatory agencies. The 12 kilovolts, excluding where applicant is required to obtain all necessary transmission lines are located within regulatory approvals and permits from all PUD Zones and those transmission federal, state, county, and local agencies lines associated with the WECS and having jurisdiction and approval related to in the BRA. the completion of the wind energy conversion system.