PART 8 General Development Standards  95 OF 148

3.  Noise setbacks. The City Council may impose  G. Impact on wildlife species and habitat. The
  a noise setback that exceeds the other  applicant shall adhere to the following regarding
  setbacks set out in this section if it deems  the impact on wildlife species and habitat:
  that such greater setbacks are necessary to
  1.  Endangered or threatened species.
  protect the public health, safety and welfare
  Development and operation of a WECS
  of the community.
  facility shall not have a significant adverse
4.  Audible noise standard. The audible noise  impact on endangered or threatened fish,
  standard due to wind turbine operations shall  wildlife, or plant species or their critical
  not be created which causes the noise level  habitats, or other significant habitats
  at the boundary of the proposed project site  identified in the City of Lackawanna
  to exceed the greater of 45 dB(A) for more  Comprehensive Plan and/or the studies and
  than five minutes out of any one-hour time  plans of the regional planning commissions
  period or 6 dB(A) greater than the prevailing  based on criteria established by federal or
  background noise.  state regulatory agencies.
5.  Operations, low-frequency noise. A WECS  2.  Migratory birds. Development and operation
  facility shall not be operated so that  of a commercial wind energy facility shall be
  impulsive sound below 20 Hz adversely  evaluated based on SEQRA findings.
  affects the habitability or use of any dwelling
  H. Unsafe and inoperable wind energy facilities; site
  unit, hospital, school, library, nursing home,
  reclamation. The applicant shall adhere to the
  or other sensitive noise receptor.
  following:
6.  Noise complaint and investigation process
  1.  Removal and site restoration. Unsafe WECS
  required. The applicant shall submit a noise
  facilities, inoperable WECS facilities and
  complaint and investigation process. The
  WECS facilities for which the permit has
  Planning Board shall determine the adequacy
  expired shall be removed by the owner
  of the noise complaint and investigation
  at his or her expense. All safety hazards
  process.
  created by the installation and operation of
F.  Fire hazard protection. The applicant shall  the commercial wind energy facility shall be
  submit a fire control and prevention program  eliminated, and the site shall be restored to
  that is appropriate and adequate for the  its natural condition to the extent feasible as
  proposed facility. The proposed program may  per Subsection B(11)(b) of this section. A bond
  include, but is not limited to, the following:  or other appropriate form of security shall be
1.  Fireproof or fire-resistant building materials.  required to cover the cost of the removal and
2.  Buffers or fire-retardant landscaping.  site restoration at the time of building permit
  application. The bond shall be payable to
3.  iAvailability of water.  the City of Lackawanna for the removal
4.  An automatic fire-extinguishing system for  of nonfunctional towers and appurtenant
  all buildings or equipment enclosures of  facilities in an amount to be determined by
  substantial size containing control panels,  the City for the period of the life of the facility.
  switching equipment, or transmission  Any fund established may consist of a letter
  equipment without regular human  of credit from a State of New York licensed
  occupancy.  financial institution. All costs of the financial
5.  Provision of training and fire-fighting  security shall be borne by the applicant.
  equipment for local fire protection personnel.