Text · page 150 of 219
Read the whole document on one page (all 219 pages, each with its own heading)
PART 11 Permit and Site Plan Procedures;Enforcement and Penalties 127 OF 148 c. Within Zone AO, new construction b. Determination of loading forces. and substantial improvements shall Structural design shall consider the have the lowest floor (including effects of wind and water loads acting basement) elevated above the highest simultaneously during the base flood on adjacent grade at least as high as the all building components. depth number specified in feet on the i. The structural design shall be community's Flood Insurance Rate Map adequate to resist water forces that enumerated in Subsection C(2) plus two would occur during the base flood. feet (at least three feet if no depth number Horizontal water loads considered is specified). shall include inertial and drag forces d. Within Zones AH and AO, adequate of waves, current drag forces, and drainage paths are required to guide impact forces from waterborne storm floodwaters around and away from debris. Dynamic uplift loads shall also proposed structures on slopes. be considered if bulkheads, walls, 4. Residential structures (coastal high hazard or other natural or man-made flow areas and Coastal A Zones). The following obstructions could cause wave runup standards, in addition to the standards in beyond the elevation of the base Subsections E(1)(a), Coastal high hazard flood. areas and Coastal A Zones, and E(1)(b), ii. Buildings shall be designed and Subdivision proposals, and Subsection constructed to resist the forces due E(2), Standards for all structures, apply to to wind pressure. Wind forces on the new and substantially improved residential superstructure include windward structures located in areas of special flood and leeward forces on vertical walls, hazard shown as Zones V1-V30, VE or V on uplift on the roof, internal forces the community's Flood Insurance Rate Map when openings allow wind to enter designated in Subsection C(2). the house, and upward force on a. Elevation. New construction and the underside of the house when substantial improvements shall be it is exposed. In the design, the elevated on pilings, columns or shear wind should be assumed to blow walls such that the bottom of the lowest potentially from any lateral direction horizontal structural member supporting relative to the house. the lowest elevated floor (excluding iii. Wind loading values used shall be columns, piles, diagonal bracing attached those required by the building code. to the piles or columns, grade beams, pile caps and other members designed to either withstand storm action or break away without imparting damaging loads to the structure) is elevated to or above two feet above base flood elevation so as not to impede the flow of water.