128 OF 148 CITY OF LACKAWANNA • NY 2026 ZONING ORDINANCE | Chapter 300: Zoning c. Foundation standards. iii Pile foundation analysis shall also include consideration of piles in i. The pilings or column foundation column action from the bottom of the and structure attached thereto structure to the stable soil elevation shall be adequately anchored to of the site. Pilings may be horizontally resist flotation, collapse or lateral or diagonally braced to withstand movement due to the effects of wind and water forces. wind and water pressures acting simultaneously on all building iv. The minimum acceptable sizes for components. Foundations must be timber piles are a tip diameter of designed to transfer safely to the eight inches for round timber piles underlying soil all loads due to wind, and eight inches by eight inches for water, dead load, live load and other square timber piles. All wood piles loads (including uplift due to wind must be treated in accordance with and water). requirements of EPEE-C3 to minimize decay and damage from fungus. ii. Spread footings and fill material shall not be used for structural support v. Reinforced concrete piles shall be of a new building or substantial cast of concrete having a twenty- improvement of an existing structure. eight-day ultimate compressive strength of not less than 5,000 d. Pile foundation design. pounds per square inch, and shall i. The design ratio of pile spacing to be reinforced with a minimum of pile diameter shall not be less than four longitudinal steel bars having 8:1 for individual piles (this shall not a combined area of not less than apply to pile clusters located below 1% nor more than 4% of the gross the design grade). The maximum concrete area. Reinforcing for precast center-to-center spacing of wood piles shall have a concrete cover of piles shall not be more than 12 feet not less than 1 1/4 inches for No. 5 on center under load-bearing sills, bars and smaller and not less than beams, or girders. 1 1/2 inches for No. 6 through No. 11 bars. Reinforcement for piles cast in ii. Pilings shall have adequate soil the field shall have a concrete cover penetration (bearing capacity) of not less than two inches. to resist the combined wave and wind loads (lateral and uplift) vi. Piles shall be driven by means of a associated with the base flood acting pile driver or drop hammer, jetted, or simultaneously with typical structure augered into place. (live and dead) loads, and shall vii. Additional support for piles in the include consideration of decreased form of bracing may include lateral or resistance capacity caused by diagonal bracing between piles. erosion of soil strata surrounding the piles. The minimum penetration for foundation piles is to an elevation of five feet below mean sea level (msl) datum if the BFE is +10 msl or less, or to be at least 10 feet below msl if the BFE is greater than +10 msl.