PART 11 Permit and Site Plan Procedures;Enforcement and Penalties  129 OF 148

  viii. When necessary, piles shall be  f. Connectors and fasteners. Galvanized
  braced at the ground line in both  metal connectors, wood connectors,
  directions by a wood timber grade  or bolts of size and number adequate
  beam or a reinforced concrete grade  for the calculated loads must be used
  beam. These at-grade supports  to connect adjoining components of
  should be securely attached to  a structure. Toe nailing as a principal
  the piles to provide support even if  method of connection is not permitted.
  scoured from beneath.  All metal connectors and fasteners
  ix. Diagonal bracing between piles,  used in exposed locations shall be steel,
  consisting of two-inch-by-eight-inch  hot-dipped galvanized after fabrication.
  (minimum) members bolted to the  Connectors in protected interior locations
  piles, shall be limited in location  shall be fabricated from galvanized sheet.
  to below the lowest supporting  g. Beam to pile connections. The primary
  structural member and above the  floor beams or girders shall span the
  stable soil elevation, and aligned in  supports in the direction parallel to the
  the vertical plane along pile rows  flow of potential floodwater and wave
  perpendicular to the shoreline.  action and shall be fastened to the
  Galvanized steel rods (minimum  columns or pilings by bolting, with or
  diameter 1/2 inch) or cable type  without cover plates. Concrete members
  bracing is permitted in any plane.  shall be connected by reinforcement,
  x.  [Knee braces, which stiffen both the  if cast in place, or (if precast) shall be
  upper portion of a pile and the beam-  securely connected by bolting and
  to-pile connection, may be used  welding. If sills, beams, or girders are
  along pile rows perpendicular and  attached to wood piling at a notch, a
  parallel to the shoreline. Knee braces  minimum of two 5/8-inch galvanized
  shall be two-by-eight lumber bolted  steel bolts or two hot-dipped galvanized
  to the sides of the pile/beam, or four-  straps 3/16-inch by four inches by 18
  by-four or larger braces framed into  inches each bolted with two 1/2-inch
  the pile/beam. Bolting shall consist  lag bolts per beam member shall be
  of two 5/8-inch galvanized steel  used. Notching of pile tops shall be the
  bolts (each end) for two-by-eight  minimum sufficient to provide ledge
  members, or one 5/8-inch lag bolt  support for beam members without
  (each end) for square members. Knee  unduly weakening pile connections. Piling
  braces shall not extend more than  shall not be notched so that the cross
  three feet below the elevation of the  section is reduced below 50%.
  base flood.

e. Column foundation design.

  i.  Masonry piers or poured-in-place
  concrete piers shall be internally
  reinforced to resist vertical and lateral
  loads, and be connected with a
  movement-resisting connection to a
  pile cap or pile shaft.