PART 11 Permit and Site Plan Procedures;Enforcement and Penalties 129 OF 148 viii. When necessary, piles shall be f. Connectors and fasteners. Galvanized braced at the ground line in both metal connectors, wood connectors, directions by a wood timber grade or bolts of size and number adequate beam or a reinforced concrete grade for the calculated loads must be used beam. These at-grade supports to connect adjoining components of should be securely attached to a structure. Toe nailing as a principal the piles to provide support even if method of connection is not permitted. scoured from beneath. All metal connectors and fasteners ix. Diagonal bracing between piles, used in exposed locations shall be steel, consisting of two-inch-by-eight-inch hot-dipped galvanized after fabrication. (minimum) members bolted to the Connectors in protected interior locations piles, shall be limited in location shall be fabricated from galvanized sheet. to below the lowest supporting g. Beam to pile connections. The primary structural member and above the floor beams or girders shall span the stable soil elevation, and aligned in supports in the direction parallel to the the vertical plane along pile rows flow of potential floodwater and wave perpendicular to the shoreline. action and shall be fastened to the Galvanized steel rods (minimum columns or pilings by bolting, with or diameter 1/2 inch) or cable type without cover plates. Concrete members bracing is permitted in any plane. shall be connected by reinforcement, x. [Knee braces, which stiffen both the if cast in place, or (if precast) shall be upper portion of a pile and the beam- securely connected by bolting and to-pile connection, may be used welding. If sills, beams, or girders are along pile rows perpendicular and attached to wood piling at a notch, a parallel to the shoreline. Knee braces minimum of two 5/8-inch galvanized shall be two-by-eight lumber bolted steel bolts or two hot-dipped galvanized to the sides of the pile/beam, or four- straps 3/16-inch by four inches by 18 by-four or larger braces framed into inches each bolted with two 1/2-inch the pile/beam. Bolting shall consist lag bolts per beam member shall be of two 5/8-inch galvanized steel used. Notching of pile tops shall be the bolts (each end) for two-by-eight minimum sufficient to provide ledge members, or one 5/8-inch lag bolt support for beam members without (each end) for square members. Knee unduly weakening pile connections. Piling braces shall not extend more than shall not be notched so that the cross three feet below the elevation of the section is reduced below 50%. base flood. e. Column foundation design. i. Masonry piers or poured-in-place concrete piers shall be internally reinforced to resist vertical and lateral loads, and be connected with a movement-resisting connection to a pile cap or pile shaft.