Text · page 153 of 219
Read the whole document on one page (all 219 pages, each with its own heading)
130 OF 148 CITY OF LACKAWANNA • NY 2026 ZONING ORDINANCE | Chapter 300: Zoning h. Floor and deck connections. joints. In lieu of the plywood, galvanized steel rods of 1/2-inch i. Wood two-by-four-inch (minimum) diameter or galvanized steel connectors or metal joist anchors straps not less than one inch shall be used to tie floor joists to wide by 1/16-inch thick may be floor beams/girders. These should be used to connect from the top installed on alternate floor joists, at a wall plate to the sill, beam, or minimum. Cross bridging of all floor girder. Washers with a minimum joists shall be provided. Such cross diameter of three inches shall be bridging may be one-by-three-inch used at each end of the 1/2-inch members, placed eight feet on center round rods. These anchors shall maximum, or solid bridging of same be installed no more than two depth as joist at same spacing. feet from each corner rod, no ii. Plywood should be used for more than four feet on center. subflooring and attic flooring to j. Ceiling joist/rafter connections. provide good torsional resistance in the horizontal plane of the structure. i. All ceiling joists or rafters shall be The plywood should not be less than installed in such a manner that 3/4-inch total thickness, and should the joists provide a continuous tie be exterior grade and fastened to across the rafters. Ceiling joists and beams or joists with 8d annular or rafters shall be securely fastened at spiral thread galvanized nails. Such their intersections. A metal or wood fastening shall be supplemented connector shall be used at alternate by the application of waterproof ceiling joist/rafter connections to the industrial adhesive applied to all wall top plate. bearing surfaces. ii. Gable roofs shall be additionally (A) Exterior wall connections. All stabilized by installing two-by-four bottom plates shall have any blocking on two-foot centers required breaks under a wall between the rafters at each gable stud or an anchor bolt. Approved end. Blocking shall be installed a anchors will be used to secure minimum of eight feet toward the rafters or joists and top and house interior from each gable end. bottom plates to studs in exterior k. Projecting members. All cantilevers and bearing walls to form a and other projecting members must be continuous tie. Continuous adequately supported and braced to 15/32-inch or thicker plywood withstand wind and water uplift forces. sheathing-overlapping the top Roof eave overhangs shall be limited to a wall plate and continuing down maximum of two feet and joist overhangs to the sill, beam, or girder-may be to a maximum of one foot. Larger used to provide the continuous overhangs and porches will be permitted tie. If the sheets of plywood are if designed or reviewed and certified by not vertically continuous, then a registered professional engineer or two-by-four-nailer blocking shall architect. be provided at all horizontal