130 OF 148  CITY OF LACKAWANNA • NY 2026 ZONING ORDINANCE | Chapter 300: Zoning

  h. Floor and deck connections.  joints. In lieu of the plywood,
  galvanized steel rods of 1/2-inch
  i.  Wood two-by-four-inch (minimum)
  diameter or galvanized steel
  connectors or metal joist anchors
  straps not less than one inch
  shall be used to tie floor joists to
  wide by 1/16-inch thick may be
  floor beams/girders. These should be
  used to connect from the top
  installed on alternate floor joists, at a
  wall plate to the sill, beam, or
  minimum. Cross bridging of all floor
  girder. Washers with a minimum
  joists shall be provided. Such cross
  diameter of three inches shall be
  bridging may be one-by-three-inch
  used at each end of the 1/2-inch
  members, placed eight feet on center
  round rods. These anchors shall
  maximum, or solid bridging of same
  be installed no more than two
  depth as joist at same spacing.
  feet from each corner rod, no
  ii.  Plywood should be used for  more than four feet on center.
  subflooring and attic flooring to
  j. Ceiling joist/rafter connections.
  provide good torsional resistance in
  the horizontal plane of the structure.  i.  All ceiling joists or rafters shall be
  The plywood should not be less than  installed in such a manner that
  3/4-inch total thickness, and should  the joists provide a continuous tie
  be exterior grade and fastened to  across the rafters. Ceiling joists and
  beams or joists with 8d annular or  rafters shall be securely fastened at
  spiral thread galvanized nails. Such  their intersections. A metal or wood
  fastening shall be supplemented  connector shall be used at alternate
  by the application of waterproof  ceiling joist/rafter connections to the
  industrial adhesive applied to all  wall top plate.
  bearing surfaces.  ii.  Gable roofs shall be additionally
  (A) Exterior wall connections. All  stabilized by installing two-by-four
  bottom plates shall have any  blocking on two-foot centers
  required breaks under a wall  between the rafters at each gable
  stud or an anchor bolt. Approved  end. Blocking shall be installed a
  anchors will be used to secure  minimum of eight feet toward the
  rafters or joists and top and  house interior from each gable end.
  bottom plates to studs in exterior  k. Projecting members. All cantilevers
  and bearing walls to form a  and other projecting members must be
  continuous tie. Continuous  adequately supported and braced to
  15/32-inch or thicker plywood  withstand wind and water uplift forces.
  sheathing-overlapping the top  Roof eave overhangs shall be limited to a
  wall plate and continuing down  maximum of two feet and joist overhangs
  to the sill, beam, or girder-may be  to a maximum of one foot. Larger
  used to provide the continuous  overhangs and porches will be permitted
  tie. If the sheets of plywood are  if designed or reviewed and certified by
  not vertically continuous, then  a registered professional engineer or
  two-by-four-nailer blocking shall  architect.
  be provided at all horizontal