Draft Wales Chapter #197 Battery Energy Storage Systems Initial Draft (dated 10/26/26) C. Annual Special Use Permit Inspections. The Town of Wales, during the annual period of Special Use Permit inspections, shall access the site and perform an annual site inspection to confirm that all provisions of the applicable Special Use Permit are in compliance. The results of the annual inspection will be reviewed and either approved or if non-compliance was identified not-approved by the Wales Town Board. In the event of non-approval, based upon inspection results or other factors, the Town will give the Applicant formal notice with a specific timeframe defined for correction of any items of non-compliance with the Special Use Permit provisions. A reinspection will be done after remedial action is taken and approved. Lack of remedial action by the applicant shall be grounds for revocation of the Special Use Permit per procedural mechanisms. oe D. Battery energy storage systems, components, and associated ancillary equipment shall have required working space clearances, and electrical circuitry shall be within weatherproof enclosures marked with the environmental rating suitable for the type of exposure in compliance with NFPA70 as currently in effect and as hereafter amended:from time to time. . E. Hazardous Materials Management, Spill Prevention, and Containment (a) Hazardous Materials Management Plan Required The Applicant shall submit a Hazardous Materials Management.Plan prepared by a qualified professional identifying all hazardous materials associated with the Battery Energy Storage System (BESS) facility, including but not limited to batteries, electrolytes, coolants, transformer oils, fire Suppression agents, and any ancillary hazardous substances. The Plan shall include: _ Sy, * i. Identification and quantities of hazardous materials to be stored on-site; ii, Safety Data, Sheets (SDs) for. applicable materials; iii. Storage methods and containment measures; iv. Spill prevention ’procedures: v... Emergency notification procedures; and vi. Procedures for handling, cleanup, transport, and disposal of contaminated materials. (b) Spil Prevention and Secondary Containment “The BESS facility shall be designed, constructed, and operated to prevent the release of »> hazardous materials to the environment. “Where hazardous liquids are present, secondary containment shall be provided in s ., accordance with applicable federal, state, and local requirements and shall be designed to ~ contain not less than one hundred ten percent (110%) of the volume of the largest individual vessel or container, unless otherwise approved by the applicable regulatory authority. (c) Firefighting Water and Contaminated Runoff Management The Applicant shall demonstrate measures to prevent contaminated runoff, fire suppression water, battery electrolyte, or debris resulting from equipment failure, thermal events, or emergency response activities from entering: i. Surface waters; TOWN OF WALES ~ BA’ ERGY STORAGE SYSTEMS