NW INV 610.97 88 17+ ST CONNECT TO EXISTING 127 LF 18" ST MANHOLE WITH TIDEFLEX ST HDPE @ CB 39 CHECK VALVE. CONNECT AT ST 0.30% RIM 614.35 EXISTING INVERT ELEVATION NE INV 611.35 ST ST 604.56±. sections 7209N and 7301 of the New York State Education Law for any person, unless acting under the direction of a registered architect, licensed engineer or land surveyor to alter this drawing. If altered such R.A., P.E. or L.L.S. shall affix his or her seal, signature, the date,the notation "Altered By" and a specific description of the alteration. ST PLUG EX. SW INV All Rights Reserved. Reuse of these documents without the expressed written permission of CARMINAWOOD DESIGN is prohibited. WARNING it is a violation of article 145 ST Greensboro ST ST 00 ST 17+ 33 LF 12" ST IO ST CB 10 HDPE @ ST PAT 1.00% CB 11 RIM 614.73 RIM 614.85 FUT ST 183 LF 48" SW INV 612.73 URE Utica ST NE INV 612.40 HDPE @ ST 130 RETA 0.50% ST SW INV 612.40 322 LF 24" HDPE @ ST ST PROPOSED PIPE CROSSING: 49 LF 12" ST MH #2 9,10 'x70' IL 0.39% ST FUT 10" SAN. INV=603.00 ST HDPE @ RIM 613.77 0 SF Buffalo RES URE D ST ST 1.00% W INV 605.48 STOP 48" STORM INV=605.05 PROPOSED STORM DRAINAGE STRUCTURES TAU RIVE 45 LF 18" NE INV 605.48 ST AND ASSOCIATED PIPING ARE SHOWN FOR RAN -TH ST 23+56 IO T 4, RU HDPE @ INFORMATIONAL PURPOSES ONLY AND WILL ST ST 28 LF 24" CB 12 T CA PAT 96 3 26 S 1.00% UT BE DESIGNED AS PART OF FUTURE IO HDPE @ ST RIM 614.76 ST SF 18+ N 00 CB 9 1.02% 21 LF 12" NE INV 611.91 DEVELOPMENT PHASES 16+ N RIM 613.85 IO ST HDPE @ NW INV 611.91 UT ST CA SW INV 611.35 1.00% +00 23+ ST 00 ST ST18 ST PROPOSED PIPE CROSSING: ST CB 13 ST ST 8" SAN. INV=603.13 RIM 614.75 ST 24" STORM INV=608.20 CB 8 ST SE INV 611.70 ST RIM 613.85 SW INV 611.70 ST ST NW INV 608.37 ST ST ST ST ST CB 7 NE INV 610.90 ST ST ST RIM 612.85 SE INV 608.37 22+ ST ST PROPOSED PIPE CROSSING: ST 00 ST SW INV 610.85 80 LF 18" 8" SAN. INV=603.15 ST ST ST ST ST CB 14 ST HDPE @ ST 48" STORM INV=605.56 RIM 615.20 ST FU ST 1.00% ST 40 LF 24" RES TURE D S INV 609.50 HDPE @ 00 ST CB 16 ST ST ST ST ST ST NW INV 609.50 15+ CB 6 290 LF 12" 0.58% RIM 615.73 TAU RIV NT 2 E-TSTORM RAPROPOSED ST West Seneca Exchange 00 T ST ST 45 LF 12" 17+ S ST HDPE @ RIM 612.85 HDPE @ 21+ 00 SE INV 609.73 HRU DRAINAGE STRUCTURES ST ST SHOWN,3W/ASSOCIATED PIPING TO BE STOP NW INV 609.17 ST 0.80% SW INV 610.00 80DURING ST 1.53% N INV 609.73 INSTALLED SF FUTURE PHASE OF WORK NE INV 610.16 ST ST ST ST ST SE INV 609.17 187 LF 48" ST Slade Ave, Ridge Rd & Orchard Park Rd CB 15 21 LF 24" STOP ST ST HDPE @ RIM 615.20 ST HDPE @ ST 0.51% ST NE INV 609.38 21 LF 18" CB 17 ST 0.57% CB 5 STOP ST SE INV 609.38 20+ HDPE @ RIM 615.73 ST PROPOSED STORM DRAINAGE STRUCTURES 00 40 LF 24" ST RIM 613.91 ST W INV 609.38 3.00% NE INV 610.63 39 LF 12" AND ASSOCIATED PIPING ARE SHOWN FOR HDPE @ ST SW INV 611.91 ST INFORMATIONAL PURPOSES ONLY AND WILL ST 0.63% CB 38 ST HDPE @00 ST + BE DESIGNED AS PART OFFFUTURE UTU ST 14 1.00% RIM 615.03 STOP ST 137 LF 18" DEVELOPMENT PHASESR RE E INV 609.13 21 LF 18" ESTA DR CB 18 ST HDPE @ CB 2 URA IVE-T HDPE @ ST SW INV 611.81 ST 1.00% PROPOSED PIPE CROSSING: 1 RIM 614.38 RIM 614.45 NT, H 9 + NW INV 609.13 00 0.52% 2,30 RU 8" SAN. INV= 604.55 NW INV 608.34 ST 00 16+ST N INV 611.64 ST ST 0 SF 24" STORM INV=609.25 95 LF 24" ST CB 4 West Seneca New York ST W INV 611.64 305 LF 48" HDPE @ CB 19 RIM 613.70 ST CB 37 13+00 ST MH #1 HDPE @ 0.73% RIM 615.03 RIM 614.38 PROPOSED PIPE CROSSING: N INV 610.54 ST NE INV 612.02 SE INV 608.23 ST ST 0.50% ST ST NE INV 611.52 RIM 612.93 CB 36 8" SAN. INV= 605.10 © CARMINA WOOD DESIGN ST ST SW INV 606.43 ST 21 LF 12" NW INV 608.23 18" STORM INV=608.15 SE INV 610.54 RIM 614.04 ST ST E INV 606.43 HDPE @ 18+ ST ST SE INV 608.44 00 STOP ST 1.00% 48 LF 18" 614 ST STOP SW INV 608.44 ST ST HDPE @ STOP ST ST 613 75 LF 18" ST 0.48% 608 ST ST HDPE @ ST 48 LF 30" 612 1.01% ST ST HDPE @ CB 20 ST 604 611 RIM 614.22 0.64% ST ST ST END SECTION 61 17+0 33 LF 12" NW INV 612.22 W/ RIPRAP PROPOSED 0PIPE CROSSING: 0 ST ST 609 HDPE @ END SECTION 0 STOP FOR 3.70% 1:4. 0 PROPOSED STORM DRAINAGE STRUCTURES 8" SAN. INV= 605.67 ST 1.6% 0 ST W/ RIPRAP 15+ AND ASSOCIATED PIPING ARE SHOWN ST 608 36" STORM INV=608.20 PROPOSED PIPE CROSSING: 21 LF 30" 1:4. ST ST ST INFORMATIONAL PURPOSES ONLY AND WILL FOREBAY 8" SAN. INV= 606.18 ST HDPE @ 0 604 BE DESIGNED AS PART OF FUTURE 608 STOP ST (1,250 CF) 18" STORM INV=608.30 STOP ST DEVELOPMENT PHASES STOP 0.62% ST 2.0% 607 47 LF 18" 16+ 171 LF 18" 00 ST ST CB 35 ST ST 15' AQUATIC BENCH 604 HDPE @ ST HDPE @ RIM 614.04 0.84% ST ST RIP-RAP PILOT 0.99% ST NE INV 608.31 Date CHANNEL 2.1% 606 ST 608 ST ST ST SW INV 608.31 1:6. STOP STOP END SECTION 7 END SECTION WITH RIPRAP, END SECTION ST ST FOREBAY W/ RIPRAP ST W/ RIPRAP 1:3. (1,250 CF) INV. 608.00. REFER TO 7 605 PROPOSED PIPE CROSSING: 1:6. INV 607.95 0 ST ST 15+ 18" STORM INV= 612.60 ST ST PLANS BY OTHERS. ST FOREBAY PROPOSED STORMWATER 604 CB 21 RIM 614.22 ST 00 42" STORM INV=608.60 60 (1,250 CF) 608 604 8 603 SW INV 611.00 ST ST ST MANAGEMENT AREA ST 00 1.1% 0 SE INV 611.00 14+ 6 WET POND (50,000 CF) 02 1:3. ST ST ST NW INV 608.47 CB 22 2.0% ST 21 LF 30" END SECTION PERMANENT POOL RIM 615.96 ST ST 604 ST HDPE @ W/ RIPRAP ELEVATION 607.80 601.80 SW INV 612.43 ST RIP-RAP PILOT No. Description ST 0.67% ST CHANNEL BOTTOM OF RIP-RAP PILOT FOREBAY NE INV 612.43 BASIN (TYP.) 1:3.0 (1,250 CF) ST ST ST CHANNEL INFORMATIONAL PURPOSES ONLY AND WILL REVISIONS: 1:6.7 ST ST 605 604 603 602 606 0.2% 607 2,92 604 STOP ST 609 608 PROPOSED PIPE CROSSING: STOP CB 34 611 610 STOP 90 LF 30" 612 8" SAN. INV= 607.02 5 G. 608 STOP STOP RIM 614.04 614 613 CB 33 RET S.F. 1:4.0 STOP HDPE @ 42" STORM INV=608.44 ST 10' WIDE BERM END SECTION WITH RIPRAP, 1:4. ST W INV 608.87 STOP RIM 614.04 0 SW INV 608.87 NE INV 608.73 0.81% 40' WIDE SPILLWAY 614 INV. 608.00. REFER TO PLANS BY OTHERS. AIL T00 SE INV 608.73 EL. 613.50 ST 13S+ STOP ST ST STOP ST ST ST ST ST ST ST ST 101 LF 24" ST ST CBSTOP HDPE @ ST 32 ST RIM 615.14 STOP 0.65% PROPOSED STORMSTOP DRAINAGE STRUCTURES ST 614.50 STOP ST 614.50 ST ST W INV 609.52 AND ASSOCIATED PIPING ARE SHOWN FOR TOP OF TOP OF Sealed 07/20/2026 ST E INV 609.52 45 LF 24" BASIN (TYP.) ST ST INFORMATIONAL PURPOSES ONLY AND WILL ST BASIN (TYP.) HDPE @ BE DESIGNED AS PART OF FUTURE ST ST 0.57% DEVELOPMENT PHASES ST ST ST CB 31 ST RIM 615.64 WET POND PLAN & DETAIL SCALE: 1"=40' TOP OF BASIN EL. = 614.50 4 APPROX. EXISTING GRADE 4 1 4 100 YR EX. VS. 100 YR PRO. EL. (Qf) = 612.22 1 1 SPILLWAY EL. = 613.50 25 YR EX. VS. 25 YR PRO. EL. (Qf) = 611.43 DRAWING NAME: 10 YR EX. VS. 10 YR PRO. EL. (Qp) = 610.89 1 YR PRO. EL. (CPv) = 609.62 Wet Pond Plan & Detail WET POND (50,000 CF) 3 FOREBAY 1 3 3 PERMANENT POOL 3 1 (1,250 CF) REFER TO PLAN FOR PIPE 1 ELEVATION 607.80 1 INV. 608.00 SIZE, LENGTH, AND SLOPE. EX. 58" X 94"" STORM PIPE 675 LF 48" HDPE @ 0.50% MITERED END SECTION 15' AQUATIC BENCH INV. = EL. 603.56 WITH CONC. EARS INLET 15' AQUATIC BENCH (15% SLOPE) INV. 607.95 (15% SLOPE) Date: 07/20/26 EX. ST. M.H. Drawn By: C. Wood RIM 697.01 Scale: As Noted SECTION THROUGH WET POND S 48" INV 604.56 (NEW) NE EX. 58" X 94" INV 603.56 DRAWING NO. SW EX. 42" INV. 604.56 (TO BE PLUGGED) NOT TO SCALE C-304 Project No: 24-4113 Page 1061 of 1174