WNY-2500056.00_HydroCAD  extreme_precip_tables_output (29) 24-hr S1 1-yr Rainfall=1.88"
Prepared by Greenman-Pedersen, Inc  Printed 12/18/2025
HydroCAD® 10.20-7a s/n 04560 © 2025 HydroCAD Software Solutions LLC  Page 18

  Summary for Subcatchment DA 3: Drainage Area 3

Runoff  =  0.33 cfs @ 12.05 hrs, Volume=  0.019 af, Depth> 1.55"
  Routed to Pond RCVR 3 : RCVR 3

Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
extreme_precip_tables_output (29) 24-hr S1 1-yr Rainfall=1.88"

  Area (ac)  CN  Description
  0.140  98  Paved parking, HSG D
  0.010  80  >75% Grass cover, Good, HSG D
  0.150  97  Weighted Average
  0.010  6.67% Pervious Area
  0.140  93.33% Impervious Area

  Tc Length Slope Velocity Capacity Description
  (min) (feet)  (ft/ft) (ft/sec) (cfs)
  6.0  19 0.0100  0.05  Sheet Flow,
  Grass: Dense n= 0.240 P2= 2.20"
  1.2  56 0.0100  0.77  Sheet Flow,
  Smooth surfaces n= 0.011 P2= 2.20"
  7.2  75 Total